7 Cleaning and servicing the heating system – Procedure
76
C
LEANING
THE
FLUE
GAS
FAN
1.
Allow the fire in the boiler to burn out and cool off.
2.
Disconnect the plug from the flue gas fan (1).
3.
Undo the four M4 hexagon socket screws (SW3) and remove the
flue gas fan (1) from the boiler.
4.
Clean the flue gas collection box (5) with a vacuum cleaner.
5.
Clean the fan wheel (3) and the annular gap behind it with a
cleaning tool.
6.
Inspect the contact surfaces (2 + 4) of the flue fan and the flue gas
collection box.
7.
Reinstall the flue gas fan in the reverse sequence.
✓
The flue gas fan has been cleaned.
Important!
✎
Observe the “Generally applicable safety instructions” in this
section.
Caution!
Risk of injury from automatically driven components
Working on the flue gas fan can lead to hand injuries due to the
moving parts.
Disconnect the boiler from the power mains when working on the
flue gas fan.