7 Cleaning and servicing the heating system – Procedure
61
2.
Loosen the M10 union nut (SW 17) (2) and pull the flue gas
temperature sensor (1) out of the clamp screw connections.
3.
Clean the sensor surface with a moist cloth.
4.
Reinstall the flue gas temperature sensor (1) in the reverse
sequence.
✓
The cleaning of the flue gas temperature sensor is completed.
C
LEANING
THE
CLEANING
SYSTEM
,
HEAT
EXCHANGER
SURFACES
AND
FLUE
GAS
FLAP
1.
Allow the fire in the boiler to burn out and cool off.
Figure 7/7 - Cleaning the flue gas temperature sensor
1
2
Important!
✎
Observe the “Generally applicable safety instructions” in this
section.
Caution!
Risk of injury from automatically driven components
Working on the flue gas fan can lead to hand injuries due to the
moving parts.
Disconnect the boiler from the power mains when working on the
flue gas fan.