6 Using the heating system – Performing the chimney sweep test
119
A
NNUAL
INSPECTION
In Germany, regular annual inspections must be carried out in
accordance with the requirements of the federal pollution limits
(1.BImschV).
B
EFORE
THE
MEASUREMENT
1.
Clean the heating system.
✎
See chapter “7 Cleaning and maintaining the heating system”,
section “7.1 Cleaning and maintenance schedule”.
2.
Check that the lambda sensor is securely mounted and tighten it
if necessary.
✎
See chapter “7 Cleaning and maintaining the heating system”,
section “7.2 Procedure”.
Once the chimney sweep is ready for the measurement:
3.
Press the
Mode
button repeatedly until the
CHIMNEY SWEEP
TEST
symbol flashes.
✓
The operating mode
CHIMNEY SWEEP TEST
has been
preselected.
4.
Press the
Enter
button.
✓
The operating mode
CHIMNEY SWEEP TEST
has been confirmed.
✓
The
CHIMNEY SWEEP TEST
symbol lights up.
✓
The heating system switches to
CHIMNEY SWEEP TEST
mode.
✓
If the HDG Hydronic equipment is connected, all of the loads will
automatically be activated to maximise the heat transfer.
✓
The display will show
No test yet
.
D
URING
THE
MEASUREMENT
Please observe the following when carrying out the chimney sweep
test:
•
Make sure that there is sufficient material in the pellet bunker to
avoid having to interrupt the measurement for reloading.
•
No fault should be present in the system.
Enter
When starting the test, the boiler temperature should not exceed
75 °C. If there is an accumulator, its temperature should not exceed
60 °C. Ensure there is sufficient heating demand placed on the
heating circuit.
Having the measurement repeated by the combustion engineer or
by HDG specialists will incur charges.