6 Using the heating system – Structure of the menus
126
1 G
ENERAL
No.
Display
Description
Date and time
Tue; 12.08.08
13:32:25
•
Date and time
To set the day of the week and date
To set the time
1-00
General
Fault buffer
display
•
Fault buffer
Displays the last faults
1-01
Boiler type
Boiler 15 kW
Boiler 25 kW
•
Boiler output
To set the boiler output according to the enclosed type
plate
1-02
Keep glow
no
yes
•
Keep glow
For switching between automatic ignition mode or
ember-sustaining mode
1-04
General
Emerg. mode active?
( 0)
0
•
Emergency operation
Enables/disables emergency operation
(0/1)
1-06
General
Operating
parameters:
save
( 0)
0
•
Save operating parameters
All current settings will be saved in a separate database.
(0/1)
1-07
General
Operating parameters:
load
( 0)
0
•
Load operating parameters
All settings will be overwritten by the database.
(0/1)
1-09
General
Initial commissioning
( 0)
0
•
Initial commissioning
All settings will be overwritten with factory settings.
(0/1)
1-10
Serial output
Status display
DAQ HCR0
•
Serial output
Defines the use of the serial interface
Only change to DAQ if a PC is connected
1-24
Language
German
French
•
Selection of the language on the display
The controller contains a maximum of three languages, in
this case German, French and English.
Table 6/3 - Service level / 1 General