7 Cleaning and maintaining the heating system – Procedure
155
12.
Reassemble the boiler in the reverse sequence.
13.
Turn the mains electricity switch on.
14.
Set the desired operating mode.
✓
The cleaning of the pellet vacuum container is completed.
C
LEANING
THE
PELLET
BUNKER
5.
Release all screws (1) of the
cover (2) with a 4 mm Allen
key.
6.
Remove the suction hose
from the suction turbine (3).
7.
Remove the cover (2).
Figure 7/19 - Removing the cover
2
1
3
8.
Clean the sieve (1) on the
underside of the cover (2)
with a vacuum cleaner.
9.
Clean the cover (2) with a
moist cloth.
Figure 7/20 - Cleaning the sieve
1
2
10.
Clean the sensor (1) with a
moist cloth.
11.
Clean the pellet vacuum
container (2) with a vacuum
cleaner.
Figure 7/21 - Cleaning the pellet vacuum container
1
2
Caution!
Danger of injury from the rotating delivery auger!
If the heating system is turned on, the delivery auger can rotate in
the pellet bunker. Hands and feet could be injured (crushed) here.
Switch the heating system off before you enter the pellet bunker.