4 Planning and installation – HDG hydraulic systems
96
HDG Hydronic
Connection
Connection
Inputs (sensors)
Outputs (units)
F1
not assigned
A1
Solar pump
H34
F2
Hot water tank top
H11 / H12
A2
District heating pump
H33
F3
Hot water tank bottom
H13 / H14
A3
Hot water pump
H28
F4
Supply CCT1
H7 / H8
A4
Heating circuit pump CCT1
H27
F5
Supply CCT2
H9 / H10
A5
Heating circuit pump CCT2
H26
F6
not assigned
A6
not assigned
F7
not assigned
A7
Heating circuit mixer CCT1
open
H31
F8
not assigned
A8
Heating circuit mixer CCT1
closed
H32
F9
District heating
temperature
H17 / H18
A9
Heating circuit mixer CCT2
open
H29
F10
Solar collector
temperature
A10
Heating circuit mixer CCT2
closed
H30
No.
Description
Notes
8-01
Select hydraulic system 7
8-03
Heating circuit control settings for use of residual heat
8-04
Set the heating system for heating circuit 1
8-05
Set the heating system for heating circuit 2
8-07
Option of activating a hot water tank
8-08
For solar heating settings
8-09
Option of activating district heating mode
8-12
Option of activating an additional heating circuit module
8-00
The settings for the hydraulic system have been
completed