Fault Description

MD 13400 / MSN 5003 7678

09/11

Blood pressure monitor

After Sales Support

Now you have purchased a ® product you can

rest assured in the knowledge that as well as your 3

years parts and labour warranty you have the added

peace of mind of dedicated helplines and web support:

0197

Blood pressure monitor

Blood pressure monitor

Medion Electronics Ltd.

120 Faraday Park

Faraday Road

Dorcan

Swindon SN3 5JF

Wiltshire, UK

In order to deal with your enquiry as quickly and

efficiently as possible, we ask you to contact our service

hotline on the number detailed below.

UK IRELAND HELPLINE NO 0871 37 61 020

(Costs 7 p/min from a BT landline;

mobile costs may be higher)

REP. IRELAND HELPLINE NO 1 800 992 508

(free phone)

To contact us by email please visit the "Service and

Support" section of our website at www.medion.co.uk

MD 13400

0871 37 61 020

1-800-992 508

free phone

costs 7p/min from a BT landline,

mobile costs may be higher

Summary of Contents for md13400

Page 1: ...monitor Blood pressure monitor Medion Electronics Ltd 120 Faraday Park Faraday Road Dorcan Swindon SN3 5JF Wiltshire UK In order to deal with your enquiry as quickly and efficientlyaspossible weaskyou...

Page 2: ...ase receipt safe as proof of date of purchase The guarantee can only be extended for the duration of any repair required During the warranty period defective devices can be returned to the service add...

Page 3: ...About this device 6 What is blood pressure 7 Notes on measurement 12 Initial operation 15 Setting the device 18 Putting on the sleeve 20 Correct measurement 21 User settings 25 Cleaning and care 30 Wa...

Page 4: ...Europe s leading manufac turers All products brought to you by health are manufac tured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfa...

Page 5: ...ren should be supervised to ensure they do not play with this device Keep plastic packaging out of the reach of chil dren There is a risk of suffocation The device is suitable for healthy adults Use t...

Page 6: ...terials If not handled correctly batteries can leak become very hot ignite or even explode which could damage your device and or your health It is very important that you follow the instructions below...

Page 7: ...expose the batteries to excessive heat such as direct sunlight fire or similar Always observe the correct polarity Make sure that the plus and minus poles are correctly inserted to avoid short circuit...

Page 8: ...lood pressure monitor helps you to take regular comparative measurements Proper use The device is used to measure blood pressure at the wrist and can save 60 measurement values in each of two memory s...

Page 9: ...With every heartbeat blood pressure fluctuates be tween a maximum value systolic when the heart pumps blood into the circulatory system and a mini mum value when the heart fills up with blood again di...

Page 10: ...The classification of blood pressure values is based on the definition and classification by the WHO World Health organisation from 1999 The WHO de fines high blood pressure as values above 140 mmHg s...

Page 11: ...8 Web Support www medion co uk Model Number 13400 9 Blood pressure classification according to WHO in mmHg 1 Normal range 2 Borderline 3 High blood pressure range 13400 EN Aldi UK Final Content indd 9...

Page 12: ...mmHg Indicator Low blood pressure 90 50 Green Normal blood pres sure 91 129 51 84 Green Borderline 130 139 85 89 Green High blood pressure I 140 159 90 99 Yellow High blood pressure II 160 179 100 109...

Page 13: ...low through them If the pressure in the sleeve is then re duced this creates a relationship between the sleeve pressure and the blood pressure The device has electronic step valves that can detect eve...

Page 14: ...a clear overview of your blood pressure by measuring it regularly and us ing clear records Everybody s blood pressure chang es constantly Fluctuations may be caused by mental and physical factors suc...

Page 15: ...ood pressure You should wait an hour after a large meal before measuring your blood pressure Do not smoke or drink alcohol before measuring your blood pressure Do not undertake any physical activity a...

Page 16: ...t on page 21 Different measurement conditions can lead to different measurement factors and therefore to markedly different values If you have recorded a value that differs greatly from your normal bl...

Page 17: ...Model Number 13400 15 Initial operation Overview of the equipment 1 User button 2 Clock button 3 ON OFF button 4 Battery compartment 5 Sleeve 6 Save button 7 WHO colour indicator 8 Display 13400 EN A...

Page 18: ...ry indicator 3 M Display of stored values 4 Systolic blood pressure value 5 Diastolic blood pressure value 6 Pulse measurement 7 Pulse display with arrhythmia detection 8 User selection 9 Display of b...

Page 19: ...AA batteries Pay attention in the process to the polarity infor mation in the battery compart ment the negative terminal faces the spring Close the battery compartment again Replace the batteries when...

Page 20: ...eries the device will change into setting mode The year flashes on the display Press the M button until the correct year is dis played Confirm your selection with the clock button and the display will...

Page 21: ...he minute setting Press the M button until the correct time is dis played Confirm your selection with the clock button and now the current time and date will appear on the display Switch off the devic...

Page 22: ...nd your wrist so that there is no gap between the sleeve and your wrist Wrap the sleeve according to the shape of your wrist If the sleeve is not firmly attached the pressure will increase and the wri...

Page 23: ...able or other supporting sur face and hold your arm so that the wrist sleeve is at heart height In doing so support your lower arm on a storage box or on a folded towel or similar You can also hold yo...

Page 24: ...d so that you can receive medical advice based on an evalua tion of these measurements Blood pressure measured at the wrist can vary from that measured at the upper arm The values may be slightly diff...

Page 25: ...d out slow ly for 5 to 10 minutes Press the clock button The battery symbol the blinking ventilation symbol and the selected user are shown on the display Do not move the sleeve your arm or hand muscl...

Page 26: ...sure ment The sleeve deflates when the measurement is com plete The systolic and diastolic blood pressure as well as the pulse and the pulse symbol appear on the dis play The data is automatically sav...

Page 27: ...r Press the clock button or user button to switch the device on The current time and date as well as the currently selected user will be shown on the display If necessary press the user button again t...

Page 28: ...er button again to select the desired user Press the M button the average measurement will be shown on the display This is indicated on the display with AVG Press the M button again in order to displa...

Page 29: ...Press the ON OFF button to switch on the de vice Press the user button again to select the desired user Press the M button the average measurement will be shown on the display Select the value to be d...

Page 30: ...deleted In order to delete all of the saved values for the se lected user repeate the first three steps until the average measurement is shown on the display This is indicated on the display by AVG Pr...

Page 31: ...rt www medion co uk Model Number 13400 29 Press the user button CL and 00 will be shown on the display All of the saved values for the se lected user have now been deleted 13400 EN Aldi UK Final Conte...

Page 32: ...onitors Cleaning storage Only use a dry soft cloth to clean the device Do not use chemical solutions and cleaning products be cause these may damage the device s surface and or inscriptions Store and...

Page 33: ...friendly material which can be recycled Device At the end of its service life the device should not be disposed of with the household rub bish Please enquire about the options for environmentally frie...

Page 34: ...ne minute Error Possible caus es and solutions Display is blank The batteries are dead Replace both bat teries with new 1 5 V R03 LR03 AAA batteries E 1 The sleeve is not fitted cor rectly Check the f...

Page 35: ...cor rectly and carry out a new measure ment E 4 An error has oc curred in the measurement Carry out a new measurement E 5 Sleeve pres sure above 300 mmHg Check the fitting of the sleeve and carry out...

Page 36: ...range Blood pressure 30 280 mmHg Pulse 40 180 beats min Power supply 2 x 1 5 V batteries R03 LR03 AAA Display LCD Memory spaces 2 x 60 measurement results Pressure build up Pressure built up automatic...

Page 37: ...Blood pressure 3mmHg pressure indicator Pulse 5 of value displayed Temperatures Operating temperature 10 40 C at humidity 30 85 Storage temperature 20 60 C at humidity 10 95 Sleeve size 13 5 19 5cm Su...

Page 38: ...2009 The device meets the requirements of electromagnet ic compatibility EN 60601 1 2 2007 If you have ques tions about electromagnetic compatibility or the val ues measured or would like to view the...

Page 39: ...37 Year of manufacture 2011 Manufacturer in accordance with guidelines for medical products MEDION AG 45307 Essen Germany The serial number of the device can be found in the battery compartment Statu...

Page 40: ...monitor Blood pressure monitor Medion Electronics Ltd 120 Faraday Park Faraday Road Dorcan Swindon SN3 5JF Wiltshire UK In order to deal with your enquiry as quickly and efficientlyaspossible weaskyou...

Page 41: ...ase receipt safe as proof of date of purchase The guarantee can only be extended for the duration of any repair required During the warranty period defective devices can be returned to the service add...