Thermostat Feature
When the WSK-MLT is in Thermostat mode, an "F" or "C" will flash
Fig. 4
in the upper right corner of the LCD display on the wall LED control
panel switch. (Fig. 3)
LCD Display
*LCD display not functioning
Fig. 5
If part or all of the LCD display on the wall control panel fails to illuminate,
replace the WSK-MLT
1. Incorrect wire of the wall switch may be the problem, Verify Wiring
Fan Check
*Fan will not turn on. No speed adjustment.
1. Verify that the WSK-MLT is wired correctly
2. Verify that there is not a limit switch for the fan installed.
*Unlike the transitional setup of a GFK-160A fan, the WSK-MLT does
not use a fan limit switch and is not plugged into the junction box.
The fan is plugged into the WSK-MLT receptacle plug labeled "Fan."
3. Verify middle plug on the receiver is label "fan"
Fig. 4
4. Verify Voltage of fan receptacle on the receiver
Typical fan readings under load
OFF - 0 Volts
Level 3 - 115 +/- 5 Volts
High
Level 2 - 94 +/- 5 Volts
Medium
Level 1 - 75 +/- 5 Volts
Low
Yes, there is Voltage
Action: Replace the Blower (107-500A)
No, there is no Voltage at fan plug receptacle on the receiver
Action: Replace WSK-MLT
*Fan will not turn off
1. Verify Fan is plugged into the WSK-MLT receiver
receptacle labeled fan
Flame Control Check
(
Authorized Technician only
)
1. Refer to
Fig. 6
, verify solenoid wiring the is correct.
2. Press "FLAME" button on the Wall Switch - flame height will change
*The flame height doesn't change
A - Verify that the correct plunger was used, blue for NG, red for LP
B - Verify the solenoid was installed with a manometer correctly
High flame 3.5" WC NG and 10" WC LP
C - Solenoid should make an audible click when the "FLAME" button
is pressed.
Yes, solenoid is good
No, solenoid or receiver is bad
D - Check Orange pigtail wires leads from the receiver with Multi meter
120v on low flame and 0v on high flame.
Fig. 6
Yes, the receiver is good
- Verify the installation of solenoid
Action: Replace solenoid if installation is correct, 125-510A
No, replace the WSK-MLT
Action: Replace WSK-MLT