27
B-1. SYSTEM PARAMETER
B. MANAGEMENT INSTRUCTIONS
No.
Classification
Description
Defaults
Function 1
Trip distance
Work-out distance (km)
Cumulative
Function 2
Total distance
Total work-out distance (LSD is 10km)
Cumulative
Function 3
Operation day
Total work- out time (days)
Cumulative
Function 4
Max frequency (Hz)
Inverter output frequency at the max. Speed(20km/h)
90
Function 5
Max speed
Max. Treadmill speed display (km/h)
20.0
Function 6
Min speed
Min. Treadmill speed ((km/h)
1.0
Function 7
Start speed
Initial treadmill start speed on ‘START’ button push. (km/h)
1.0
Function 8
Max incline (AD)
Incline sensor value at the max. inclination
590
Function 9
Min incline (AD)
Incline sensor value at the min. Inclination
60
Function 10
Incline AD tolerance
Grade command protocol - Don’t change without proper reasons.
5
Function 11
Max Incline
Max inclination display (%)
16
Function 12
Min Incline
Min inclination display – means inclination below 0% (-%) / Don’t change
without proper reasons
0
Function 13
Motor direction
Treadmill’s Operation Direction
0 : Normal Direction
1 : Reverse Direction
0
Function 13
Time OP mode
Manual Workout Time Limitation
1 : Limitation On
0 : Limitation Off
0
Function 14
Time OP time
Time Limitation Setting in Manual Workout (min) – When No.13 is enabled
30
Function 15
Free run E stop
1 : End the motor by Free Run
0 : End the motor by speed decreasing
0
Function 16
E stop S/D control
0 : Emergency Stop during Emergency Button is pressed
1 : Emergency Stop after change the condition of Emergency button
1
Function 17
E stop A/B contact
1 : Emergency Button - B-type contact
0 : Emergency Button - A-type contact
1
Function 18
CPE max Speed
CPR mode max speed limit (km/hr)
20.0
Function 19
CPE min Speed
CPR mode min speed limit (km/hr)
1.0
Function 20
CPE start Speed
Initial start speed at CPR mode (km/hr)
1.0
Function 21
CPE delta Speed
Decreament speed at CPR mode (km/hr) - Increament is always 1
1.0
Function 22
CPE speed control time
CPR mode speed control time interval(sec)
15
Function 23
CPE max incline
CPR mode max inclination(%)
16
Function 24
CPE min incline
CPR mode min inclination(%)
0
Function 25
CPE delta incline
Decreament inclination at CPR mode(%) - Increament is always 1
1
Function 26
CPE incline control time
CPR mode inclination control time interval(sec)
30
Function 27
Auto stop mode
Auto Stop Setting
1 : On
0 : Off
1
Function 28
Auto stop time
Auto Stop Time Setting(Sec)
10
Function 29
Auto stop sensor tune
Change the sensitivity of Auto Stop Sensor (More sensitive at low value)
75
Function 30
Language
Language (0 : English)
0
Function 31
Unit
MKS 1 : LBS
MKS