Thank you for choosing the Advantage Rail / Pole from HealthCraft. Please
read and understand the instructions in this manual; keep manual for future
reference. It is your responsibility to see that your Advantage Rail / Pole is
properly assembled, installed, and cared for. Failure to follow instructions in
this manual could result in serious injury or death. If you are not equipped to
undertake the outlined work, we would recommend that you have your
Advantage Rail / Pole installed by a qualified contractor.
The Advantage Rail is a high quality, commercial grade pivoting and locking
horizontal bar that connects to a floor mounted mast. The horizontal bar can be
lifted, pivoted and lowered to the next locking position around the mast. The
Advantage Rail is intended for moderate vertical and horizontal load bearing to
provide sitting and standing support for people with reduced mobility. The
Advantage Rail mast is installed to a structural floor. Inside the mast is a
locking mechanism for the horizontal bar: a castellated collar with 8 grooves
(every 45 degrees) to provide a mechanism strong enough to support the user.
It is important to set proper height and orientation of the Advantage Rail to
optimize the user’s range of motion. The maximum user weight is dependent
on model. Note: Product is not intended to support full body weight. The
Advantage Rail is not to be used in any other way than described above.
The Advantage Pole is a high quality, commercial grade floor mounted support
pole. The Advantage Pole is intended for moderate vertical and horizontal load
bearing to provide sitting and standing support for people with reduced mobility.
The Advantage Pole mast is installed to a structural floor. The maximum user
weight is dependent on model. Note: Product is not intended to support full
body weight. The Advantage Pole is not to be used in any other way than
described above.
WARNING - PATIENT ENTRAPMENT (see additional guidelines)
The potential risk of entrapment (limb, neck, head, torso) between the bed rail
and adjacent item (i.e. mattress, headboard, sidetables, etc.) can be reduced
or avoided by the following strategies:
1. Situate the bed rail at a distance that is considerably smaller or larger than
that which could result in entrapment.
2. Consider situations that could change with time or usage such as mattress
compression, patient movement, bed position changes due to electrically
powered beds, etc.
3. Realize that this product is not intended as a physical constraint or barrier to
exiting the bed.
LIMITED LIFETIME WARRANTY
Products are covered by a limited lifetime warranty against defects in materials
and workmanship for the original purchaser. Warranty excludes products that
have been damaged through misuse, accidental damage, alteration, normal
wear and tear, wood material and stain, or the use of corrosive or abrasive
cleaning products.
Buyer hereby indemnifies, agrees to hold harmless and defend HealthCraft
Products Inc. from and against any and all liabilities, claims, (founded and
unfounded), losses, damages, costs and expenses (including without limitation
consequential damages and reasonable professional fees) resulting from
buyers specification, application, or improper use of goods described hereon;
buyers omission or neglect. HealthCraft Products Inc. does not assume any
liability for damage resulting from services performed by others or faulty
installation, misuse or misapplication of goods sold by HealthCraft Products
Inc. HealthCraft Products Inc. shall not be liable for prospective profits or
special, indirect, or consequential damages, or for the cost of any corrective
work done without HealthCraft Products Inc. prior approval. HealthCraft
Products Inc. total liability hereunder shall in no event exceed the purchase
price of the goods specified hereon. Specifications subject to change without
notice.
HealthCraft Products Inc.
2790 Fenton Road
Ottawa, Canada
K1T 3T7
Gate 88
Kanalgatan 45B
Skellefteå, Sweden
93123
DELIVERY CONTENTS - ADVANTAGE RAIL
FIGURE A.
1. T-Handle Assembly
2. Pivot Bushing
3. Mast Assembly
4. Base Cover
5. Pivot Sleeve
DELIVERY CONTENTS - ADVANTAGE POLE
FIGURE B.
11. Pole Assembly
INSTALLATION WARNINGS
FIGURE C.
1. Mast must be installed to floors that are structurally sound.
2. Ideal if mast can be aligned and secured directly to floor joist.
3. If desired installation location does not have adequate structure, add wood blocking.
4. If mounting mast to concrete, use appropriate methods and fasteners (not
included): example: 5/16” sleeve or wedge type anchor is recommended
5. CAUTION - do not install if structure behind walls is unknown.
Supplied fasteners for wood structure only (minimum thread engagement 2" /
51mm). If using other fasteners, ensure screw retention force rating at least
600lbs/272kgs (800lbs/360kgs for HD).
ADVANTAGE RAIL / POLE PLACEMENT
FIGURE D.
1. BEDROOM - Locate pole adjacent to waistline, and as close to bed as
possible while allowing clearance for bed coverings.
2. BATHTUB ONLY - Locate pole base against tub, approximately half way
along its length
3. SEATING (TOILET or CHAIR) - To provide clearance when standing, locate
pole 3-10" / 76mm-254mm forward of the knees, and 2-6" / 51mm-154mm to
the side of knees when sitting.
SUGGESTED ADVANTAGE RAIL POSITIONS
FIGURE D.
4. BEDROOM
A = side support / out of the way
B = in-bed support
C = sitting support
D = standing support
E = transfer support to
walker / wheelchair
MAST INSTALLATION
FIGURE E.
1. Note the orientation of the 8 locking positions in relation to the floor plate.
2. Secure mast to floor using fasteners appropriate to the floor material.
3. Slide base cover down the mast.
4. Remove set screw using hex key.
5. Remove pivot bushing from mast.
ADVANTAGE RAIL ASSEMBLY / INSTALLATION
FIGURE F.
6. Slide pivot bushing and pivot sleeve onto handle, and align hole on pivot
sleeve with the corresponding hole on rail to set height.
7. Insert pin thru pivot sleeve and rail.
8. Lower handle assembly into the top of the mast.
9. Align hole of pivot bushing with mast, and secure with set screw.
ADVANTAGE POLE ASSEMBLY / INSTALLATION
FIGURE G.
10. Lower handle assembly into the top of the mast.
11. Align hole of pivot bushing with mast, and secure with set screw.
TECHNICAL DATA
See Figure H.
PRODUCT USAGE
See Figures I & J.
10
EC
REP
Summary of Contents for Advantage Pole AR-AP-HD
Page 1: ...1 Advantage Pole AR AP HD Advantage Rail AR T AR T HD AR TA DC104 RevC healthcraftproducts com...
Page 2: ...A 5 6 9 10 7 8 1 2 3 4 2...
Page 3: ...B 12 9 10 7 8 11 2 3 4 3...
Page 4: ...C 4 1 2 3 4 5 MIN 2 51mm...
Page 5: ...D 5 2 51mm 6 152mm 3 76mm 10 254mm A B C D E A B C E D F A C E B D 4 5 6 1 2 3...
Page 6: ...E 6 2 3 5 4 1...
Page 7: ...G F 30 762mm 32 813mm 34 864mm 36 914mm 38 965mm 7 6 7 8 9 10 11...
Page 9: ...I J 9...