19
2010/2/26 Ver1.0+V1.0
standby directly to choose.
4.
After setting parameter, press
or press
during setting to start program (It
will be start by default if there is no parameter need to be adjust).The target value will be
carried out by count down. (Parameter will make measure according value you enter)
5.
Under THR mode, the target heartbeat value will automatically calculate according to the
input age of users.
6.
If it can’t detect pulse, it will shoe NO PLUSE on the screen. If it can’t detect pulse for 45
seconds, it will turn back to standby itself.
7.
RPM need be from70RPM to 80RPM during training. If RPM can’t reach 70RPM, it will
show ”RPM
↑
”on the screen. If RPM rather than 80RPM, it will show ”RPM
↓
”on the
screen
8.
HR CONTROL Mode
:
Preset heartbeat control mode is 50W (Level2). When computer detects the pulse, the
heartbeat value will be judged every 10 seconds.
Judgment method of Heartbeat value as follows:
A.
While running, program will compare actual heartbeat value with preset
heartbeat value. If
actual heartbeat value
≦
preset heartbeat value 15,
WATT
will increase 20 automatically, the highest can reach 400 WATT.
B.
While running, program will compare actual heartbeat value with preset
heartbeat value. If
actual heartbeat value
≦
preset heartbeat value 5,
WATT
will increase 10 automatically, the highest can reach 400 WATT.
C.
While running, program will compare actual heartbeat value with preset
heartbeat value. If
actual heartbeat value
≧
preset heartbeat value 5,
WATT
will decrease 10 automatically, the lowest can reach 50WATT.
D.
While running, program will compare actual heartbeat value with preset
heartbeat value. If
actual heartbeat value
≧
preset heartbeat value 15,
WATT
will decrease 20 automatically, the lowest can reach 50WATT.
9.
While running, program will compare actual heartbeat value with preset heartbeat value. If
actual heartbeat value
≧
preset heartbeat value 30,
WATT will decrease down to
50WATT. The program will not carry out until
heartbeat value
≦
preset heartbeat value
5.
10.
This chart is about Age and Pulse Value (default value) for THR Function.
Summary of Contents for HC10TVUB
Page 5: ...4 2010 2 26 Ver1 0 V1 0 Assembly Parts...
Page 24: ...23 2010 2 26 Ver1 0 V1 0 Program Control Project Figure level review...
Page 25: ...24 2010 2 26 Ver1 0 V1 0...
Page 26: ...25 2010 2 26 Ver1 0 V1 0...
Page 27: ...26 2010 2 26 Ver1 0 V1 0...
Page 28: ...27 2010 2 26 Ver1 0 V1 0...
Page 29: ...28 2010 2 26 Ver1 0 V1 0...
Page 30: ...29 2010 2 26 Ver1 0 V1 0...
Page 31: ...30 2010 2 26 Ver1 0 V1 0...
Page 32: ...31 2010 2 26 Ver1 0 V1 0...
Page 33: ...32 2010 2 26 Ver1 0 V1 0...
Page 34: ...33 2010 2 26 Ver1 0 V1 0...
Page 35: ...34 2010 2 26 Ver1 0 V1 0...