Hearing Products International Limited
Echo House, 26/27 Haigh Park, Stockport, SK4 1QR, England
Tel. +44 (0) 161 480 8003
Fax +44 (0) 161 480 8006
www.hear4you.com
Hearing Products International Ltd. reserve sole right to
alter prices, design and/or technical specifications or
colours without prior notice. E & O.E. 06/2016 V2
Echochime300TM Instructions.
Copyright Hearing Products International limited 06/2016 V2
UK: Waste electrical products and batteries should not be disposed of
with household waste. Separate disposal facilities exist, for your
nearest facilities see www.recycle-more.co.uk or Hearing Products
International Limited for full details www.hear4you.com.
The telephone signaler works with the
receiver (chime), and must be
paired before using.
Step 1: Insert battery to the telephone
transmitter.
Step 2: Insert batteries to the receiver
(chime).
Step 3: Enter pairing mode for receiver
(chime unit). Press and hold the
zone selector button 3 seconds.
The LED #1 will flash.
Step 4: Press the button again to select
zone with the telephone icon.
Press melody selector to scroll
through the melodies. Once you hear
t h e t e l e p h o n e
sound, do not press again as it is now selected.
Step 5: Once you have selected the zone and sound, press the
test button on the telephone signaler once. If successful,
the receiver will generate a short tone. Press the
button
to exit pairing mode it is now ready to use.
The sensor pad transmitter works with
the receiver (chime) and must be paired
before using.
Step 1: Insert battery to the sensor.
Step 2: Insert batteries to the receiver
(chime).
Step 3: Enter pairing mode for receiver
(chime unit).
Press and hold the zone
selector button 3 seconds.
The LED #1 will flash.
Step 4: Press the button again to
move to the zone you want to
pair with.
Press melody selector to
scroll through the melodies. Once you hear
your preferred melody, do not press
again as it is now selected.
Step 5: Once you have selected the zone and melody, trigger
the sensor pad transmitter by press the test button.
If successful, the receiver will generate a short tone.
Press the
button to exit pairing mode, the system
is now ready to use.
+
CR٢٠٣٢
Part & Function
Battery installation
Test
Telephone Plug
Rj11
Battery
compartment
Open the cover
Code Matching & Melody Selection
Operation
Code Conflict
If the telephone signaler coding is the same as another transmitter
you must change the code. When you have changed the code re-
pair the telephone signaler.
+
+
CR٢٠٣٢
Open the cover
Remove the battery
Press and hold the test button, insert
the battery whilst holding the button
for 5 seconds. The LED will flash 5 times
when a new code is generated
10
11
Plug the telephone line into the telephone socket as the diagram.
The system is ready to use.
Battery Installation
Code Matching & Melody Selection
LED indicator
Parts and Function
Align mark
Function switch
Battery
compartment
Battery cover
Open battery cover
Buzzer
Magnet
The magnetic sensor works with the receiver (chime)
And must be paired before using
Step 1: Insert batteries to the sensor.
Step 2: Insert batteries to the
receiver (chime).
Step 3: Enter pairing mode for receiver
(chime unit).
Press and hold the zone
selector button 3 seconds.
The LED #1 will flash.
Step 4: Press the button again to move
to the zone you want to pair with.
Press melody selector to scroll
through the melodies. Once you
hear
your preferred melody, do not press
again as it is now selected.
Step 5: Once you have selected the zone and melody, trigger
the magnetic sensor by holding the sensor and magnet
together, then move them apart.
If successful, the receiver will generate a
short tone. Press the
button to exit
Pairing mode, the system is now ready to
use.
ID
Zone selector
button
Melody
selector
C
H
IM
E
L
IG
H
T
L
IG
H
T & C
H
IM
E
Installation
Install two CR2032 batteries to the battery compartment.
Remove the back paper of the double sided tape on the back of the
unit.
Stick the alarm unit to the window/door frame and the magnet unit
to the door/window by the side of the alarm unit..
When the magnet moves away from the
alarm unit, the alarm or bell will be activated
and send out a signal to the receiver
(chime).
Alarm Mode
The alarm sound will automatically turn off
within 15 seconds and sound again 30
seconds later if the door or window does not
close.
Bell Mode:
The bell will generate a Ding Dong tone and
sound again 30 seconds later if the door
does not close.
Using as visitor sensor:
Slide the switch to bell
position
Using as alarm sensor:
Slide the switch to siren
position
12
13
ID
Zone selector
button
Melody
selector
C
H
IM
E
L
IG
H
T
L
IG
H
T & C
H
IM
E
14
15
16
16
17
18
PIR lens
LED indicator
Mounting backet
9V battery
(6F22)
Part & Function
Battery Installation
The PIR sensor works with the receiver (chime)
and must be paired before using
Step 1: Insert battery to the sensor.
Step 2: Insert batteries to the receiver (chime).
Step 3: Enter pairing mode for receiver (chime
unit).
Press and hold the zone selector
button 3 seconds. The LED #1 will flash.
Step 4: Press the button again to move to
the zone you want to pair with.
Press melody selector to scroll
through the melodies. Once you hear
your preferred melody, do not press
again as it is now selected.
Step 5: Once you have selected the zone and
melody, trigger the PIR sensor once.
To trigger the sensor move your hand
across the lens.
If successful, the receiver will generate
a short tone. Press the
button to exit
pairing mode, the system is now ready
to use.
ID
Zone selector
button
Melody
selector
C
H
IM
E
L
IG
H
T
L
IG
H
T & C
H
IM
E
Test the Sensor
Insert the battery into the PIR detector, the PIR detector will start to
detect motion automatically after 15 seconds. Walk to the front of
the detector within 8m.
Once the motion has been detected, the detector will send out a
trigger signal to the receiver (chime) then go into a sleep mode for
10 seconds. During this time it will not detect motion.
C
RoHS
Part & Function
Battery
I
nstallation
Mono jack for
External sensor
Battery
compartment
Insert a CR2032
Battery "+" face up
Mode Switch
for bed pad
or Fall Mat
+
+
Call/Test
button
LED
SENSOR PAD TRANSMTTER
* Unlock the screw
* Slide to open the
cover
Setting
If the
sensor pad transmitter
coding
is
same as another transmitter
,
you must change the code. When you have changed the code
.
re-pair
the
sensor pad transmitter
.
Open the cover
Remove the battery
+
+
+
+
Mat
Pad
+3S
+10min
Code Conflict
Press and hold the test button,
insert the battery whilst holding
the button for 5 seconds. The LED
will flash 5 times when a new code
is generated
Open the battery cover and slide the switch to
pad or mat position
Mat: for fall mat (normal open)
Pad: for Bed pad or chair pad (normal close)
+3S: Pad mode with 3 seconds delay
+10min: Pad mode with 10 minutes delay.
OPERATION
Connection
1. open the battery cover
2. Connect the pressure
pad to the transmitter
3. close the battery cover
o 2.5 mono plug
/
Mat
EXIT
Mat
Pad
+
+3S
+10min
The transmitter will send out the alert signal to the receiver, when
someone steps on (falls on) the mat
Pad
+
+
Mat
Pad
+3S
+10min
When the patient has left the mat, the transmitter will send an alert
signal to the receiver.
Pad Delay Mode
To prevent false trigger. you can slide the mode switch to Pad + 3S
or Pad + 10min position. When the sensor is triggered, The timer will
start. When the timer is over, the sensor will send the alert signal to
ring the receiver. Pressing the Call/Test button once will stop the
timer after trigger. This means the sensor will return to standby
mode and does not ring the receiver.
** The sensor pad transmitter can be connected to other type of
sensor such as a switch.
Using as a call button
1. Open the battery cover
2. Push the Lanyard
into
the gap
3. Pull the Lanyard to hold on the
column
4. Close the battery cover
When the person needs
help press the call button
once.
ID
Zone selector
button
Melody
selector
C
H
IM
E
L
IG
H
T
L
IG
H
T & C
H
IM
E