background image

Hearing Products International Limited

Echo House, 26/27 Haigh Park, Stockport, SK4 1QR, England 
Tel. +44 (0) 161 480 8003 
Fax +44 (0) 161 480 8006 

www.hear4you.com

Hearing Products International Ltd. reserve sole right to
alter prices, design and/or technical specifications or
colours without prior notice. E & O.E. 06/2016 V2
Echochime300TM Instructions.

   

Copyright Hearing Products International limited 06/2016 V2

UK: Waste electrical products and batteries should not be disposed of
with household waste. Separate disposal facilities exist, for your
nearest facilities see www.recycle-more.co.uk or Hearing Products
International Limited for full details www.hear4you.com.

The  telephone  signaler  works  with  the 

receiver  (chime),  and  must  be 
paired before using.

Step 1:  Insert  battery  to  the  telephone 

transmitter.

Step 2:  Insert  batteries  to  the  receiver 

(chime).

Step 3:  Enter  pairing  mode  for  receiver 

(chime  unit).  Press  and  hold  the         
zone  selector        button  3  seconds.           
 The LED #1 will flash.

Step 4:  Press the     button again to select
  

zone with the telephone icon.

       

Press     melody selector to scroll 

            through  the  melodies.  Once  you  hear   

t h e   t e l e p h o n e  

sound, do not press  again as  it  is now selected.

Step  5:  Once  you  have  selected  the  zone  and  sound,  press  the 

test  button  on  the  telephone  signaler  once.  If  successful, 
the receiver will generate a short tone. Press the   

 

button 

to exit pairing mode it is now ready to use. 

The sensor pad transmitter works with 
the receiver (chime) and must be paired 
before using.
Step 1:   Insert battery to the sensor.
Step 2:   Insert batteries to the receiver 

(chime).

Step 3:   Enter pairing mode for receiver 

(chime unit). 

       

Press and hold the      zone 
selector  button 3 seconds.

       

The LED #1 will flash.

Step 4: Press the      button again to 

move to the zone you want to 
pair with.  

       

Press       melody selector to 
scroll  through the melodies. Once you hear

 

your preferred melody, do not press 

 

again as it is now selected. 

Step 5:   Once you have selected the zone and melody, trigger 

the sensor pad transmitter by press the test button. 

  

If successful, the receiver will generate a short tone. 
Press the 

    

button to exit pairing mode, the system 

is now ready to use.

+

CR٢٠٣٢

Part & Function

Battery installation

Test

Telephone Plug
Rj11

Battery
compartment

Open the cover

Code Matching & Melody Selection

Operation

Code Conflict

If the telephone signaler coding is the same as another transmitter 
you must change the code. When you have changed the code re-
pair the telephone signaler. 

+

+

CR٢٠٣٢

Open the cover

Remove the battery

Press and hold the test button, insert 
the battery whilst  holding  the button 
for 5 seconds. The LED will flash 5 times 
when a new code is generated

10

11

Plug the telephone line into the telephone socket as the diagram. 
The system is ready to use.

Battery Installation

Code Matching & Melody Selection

LED indicator

Parts and Function

Align mark

Function switch

Battery 
compartment

Battery cover

Open battery cover

Buzzer

Magnet

The magnetic sensor works with the receiver (chime) 
And must be paired before using
Step 1:   Insert batteries to the sensor.
Step 2:   Insert batteries to the 

receiver (chime).

Step 3:   Enter pairing mode for receiver 

(chime unit). 

       

Press and hold the      zone 
selector  button 3 seconds.

       

The LED #1 will flash.

Step 4: Press the      button again to move 

to the zone you want to pair with.  

       

Press       melody selector to scroll 

 

through the melodies. Once you 

hear

 

your preferred melody, do not press 

 

again as it is now selected.

       

  

Step 5:   Once you have selected the zone  and melody, trigger 

the magnetic sensor by holding the sensor and magnet 
together, then move them apart. 

  

If successful, the receiver will generate a

 

short tone. Press the 

    

button to exit

 

Pairing mode, the system is now ready to 
use.

ID

Zone selector
button

Melody 
selector

C

H

IM

E

L

IG

H

T

L

IG

H

T & C

H

IM

E

Installation

Install two CR2032 batteries to the battery compartment.
Remove the back paper of the double sided tape on the back of the 
unit.
Stick the alarm unit to the window/door frame and the magnet unit 
to the door/window by the side of the alarm unit..

When  the  magnet  moves  away  from  the 
alarm unit, the alarm or bell will be activated 
and  send  out  a  signal  to  the  receiver 
(chime).

Alarm Mode

The alarm sound will automatically  turn off 
within 15 seconds and sound again 30 
seconds later if the door or  window does not 
close.

Bell Mode:

The bell will generate a Ding Dong tone and 
sound again 30 seconds later if the door 
does not close.

Using as visitor sensor:
Slide the switch to bell 
position

Using as alarm sensor:
Slide the switch to siren 
position

12

13

ID

Zone selector
button

Melody 
selector

C

H

IM

E

L

IG

H

T

L

IG

H

T & C

H

IM

E

14

15

16

16

17

18

PIR lens

LED indicator

Mounting backet

9V battery
(6F22)

Part & Function

Battery Installation

The PIR sensor works with the receiver (chime) 
and must be paired before using
Step 1: Insert battery to the sensor.
Step 2: Insert batteries to the receiver (chime).
Step 3: Enter pairing mode for  receiver (chime 

unit). 

       

Press and hold the      zone selector 
button 3 seconds. The LED #1 will flash.

Step 4: Press the     button again to move to  

the zone you want to pair with.  

       

Press      melody selector to scroll 
through the melodies. Once  you hear 
your preferred melody, do not  press 
again as it  is now selected.

       

  

Step 5: Once you have selected the zone and 

melody,  trigger the PIR sensor once.

       

To trigger the sensor move your hand 
across the lens.       

       

If successful, the receiver will generate 
a short tone. Press the   

 

button to exit 

pairing mode, the system is now ready 
to use.

ID

Zone selector
button

Melody 
selector

C

H

IM

E

L

IG

H

T

L

IG

H

T & C

H

IM

E

Test the Sensor

Insert the battery into the PIR detector, the PIR detector will start to 
detect  motion  automatically  after  15  seconds.  Walk  to  the  front  of 
the detector within 8m.
Once  the  motion  has  been  detected,  the  detector  will  send  out  a 
trigger signal to the receiver (chime) then go into a sleep mode for 
10 seconds. During this time it will not detect motion.

C

RoHS

Part & Function

Battery 

I

nstallation

Mono jack for
External sensor

Battery
compartment

Insert a CR2032 
Battery "+" face up

Mode Switch 
for bed pad 
or Fall Mat

+

+

Call/Test
 button

LED

SENSOR PAD TRANSMTTER

* Unlock the screw
* Slide to open the 
   cover

Setting

If  the 

sensor  pad  transmitter

  coding 

is

  same  as  another  transmitter

,

 

you must change the code. When you have changed the code

.

 re-pair 

the 

sensor pad  transmitter

Open the cover

Remove the battery

+

+

+

+

Mat
Pad
+3S

+10min

Code Conflict

Press  and  hold  the  test  button, 
insert  the  battery  whilst    holding   
the button for 5 seconds. The LED 
will flash 5 times when a new code 
is generated

Open the battery cover and slide the switch to 
pad or mat position 

Mat: for fall mat (normal open)
Pad: for Bed pad or chair pad (normal close)
+3S: Pad mode with 3 seconds delay
+10min: Pad mode with 10 minutes delay.

OPERATION

Connection

1. open the battery cover
2. Connect the pressure 
    pad to the transmitter
3. close the battery cover

o 2.5 mono plug

/

Mat

EXIT

Mat
Pad

+

+3S
+10min

The transmitter will send out the alert signal to the receiver, when 
someone steps on (falls on) the mat

Pad

+

+

Mat
Pad
+3S
+10min

When the patient has left the mat, the transmitter will send an alert 
signal to the receiver.   

Pad Delay Mode

To prevent false trigger. you can slide the mode switch to Pad + 3S 
or Pad + 10min position. When the sensor is triggered, The timer will 
start. When the timer is over, the sensor will send the alert signal to 
ring  the  receiver.  Pressing  the  Call/Test  button  once  will  stop  the 
timer  after  trigger.  This  means  the  sensor  will  return  to  standby 
mode and does not ring the receiver.

**  The  sensor  pad  transmitter  can  be  connected  to  other  type  of 
sensor such as a switch.

Using as a call button

1. Open the battery cover
2. Push the Lanyard

into

the gap

3. Pull the Lanyard to hold on the   

column

4. Close the battery cover

When the person needs 
help press the call button 
once.

ID

Zone selector
button

Melody 
selector

C

H

IM

E

L

IG

H

T

L

IG

H

T & C

H

IM

E

Reviews: