4
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
Figure 7.
Note:
Electrical service of 120 VAC-60Hz must be supplied
to the junction box of the fi replace in order for the power vent
to operate correctly.
4. Remove any cover or plate protecting valve and
module wiring assembly or switch.
5. Unplug two brown wires on the green module and
plug into red and brown wires from wiring harness
terminal block.
Service Parts List
Description
Part Number
Power Vent Cap Assembly
2026-018
Blower Power Vent
655-500
Vacuum Switch
655-522
Wire Harness Water Proof
655-531A
Power Vent Support Bottom
655-100
Power Vent Support Top
655-101
Wire Harness
2065-112
10” Wire Assembly
2065-114
Firestop
2045-006
Hardware Bag
655-900A
6. Plug one end of the black wire harness into one
of the HOT terminals on the junction box. Plug
the other female end into the back of the rocker
switch, where the brown wires were removed in
Step 6.
7. Plug the white wire from the terminal block har-
ness into one of the NEUTRAL terminals of the
junction box.
8. Plug the black wire from the terminal block har-
ness into the back of the rocker switch.
WARNING: ON/OFF switch and remote wires are
high voltage (120 VAC). Use proper wire.
9. Attach terminal block to base of fi replace using
Velcro pads provided.
10. Remove battery box unplugging red and black
wires. (Battery backup will not work with PVK-80
installed.)
11. Replace any covers or plates removed in Step B.
12. Cable tie the wires together so that no wire is in
contact with the top of the cavity under the fi re-
place.
13. Reconnect electrical power supply to the junction
box.