B. Convection Blower Replacement
1. Turn down the thermostat, let appliance completely
cool and then unplug appliance before servicing.
2.
The convection blower is located on the floor at the
rear of the appliance.
3. Follow section on
Side Curtain Replacement
on
to remove left side curtain from the appliance.
4.
Release blower wires from the nylon wire retainer if
applicable. Your PS35 has 2 black wires.
5.
Remove the wing bolt and move the blower and hold-
down bracket toward the back of the appliance to
release the locating tab
(Figure 24.3)
. Pull the blower
out from under the convection plenum. Slide the blower
out of the appliance. Disconnect the wires from the
spade connectors at this time
(Figure 24.4)
.
6.
Return wires to nylon wire retainer. Make sure wires
do not contact any moving parts or touch any surfaces
that may become hot
(Figure 24.4)
.
A. Side Curtain Replacement
1.
Lift the hopper lid up until it locks into place.
2.
Using a Phillips screwdriver, a 3/8 inch wrench, or a 3/8
inch socket, loosen the three (3) bolts from the back
side of the appliance
(Figure 24.1)
.
3.
Remove the upper and lower side panels by lifting up
and out. The hooks on the panels will slide out of the
slots on the appliance
(Figure 24.2)
.
5
Service Parts Replacement
Figure 24.1
Figure 24.2
Figure 24.3
Figure 24.4
NOTE:
If conducting other service part replacements, do
it at this time:
-
Right side: Feed motor, vacuum switch, and
combustion blower
(Figure 30.3 on
.
-
Left side: Control box, convection blower,
fuse, junction box, and red call light
(Figure 30.2 on
)
.
4. Add new side curtain in reverse order.
Loosen Screws,
Do Not Remove.
Nylon Wire Retainer
Wing Screw
Hold Down Bracket
Spade
Connectors
Locating Tab
Upper Left
Panel
Lower Left Panel
Lift Up and Out of Slots