Hearth & Home Technologies • B41L-AU Owner Manual • 2570-981 Rev. B • 5/20
14
H. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 4.B.
• Clean fixed glass assembly. See Section 4.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
Note:
Some IPI systems have a safety feature that
automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE!
Open windows for air circulation during fire
-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
Optional Heat-Zone
®
- 240V Gas Kit
The HEAT-ZONE
®
-240V G
AS
heat management op
-
tion is available for use with the B41L-AU appliance and
must be used in conjunction with the RC300 control. The
Heat-Zone-240V Kit draws heat from your fireplace to an
adjacent room in your home, up to 20 ft (6 m) away.
Optional Passive Heat Kit (PH-FRT/PH-SIDE)
The Passive Heat heat management option is available
for use with the B41L-AU appliance. The Passive Heat
Kit allows the heat to be vented into the room through one
front discharge, two side discharges or an open top dis
-
charge while the fireplace is in operation. Passive Heat
can be used in conjunction with
HEAT-ZONE
®
- 240V Gas
Kit or HEAT-OUT-GAS
kit. Passive Heat is not compat
-
ible with optional fan kit.
I. Heat Management
Burn Rate
The B41L-AU model has a variable burn rate which is
controlled by the remote control. Therefore the flame
height is adjustable.
The flame height may be adjusted as desired by locating
the flame option on the remote control and adjusting up or
down to desired flame height.
An optional heat management system, which allows the
heat from the appliance to be redirected as desired, may
be installed with this appliance. It may be either a Heat-
Zone
®
- 240V, which diverts heat into an adjacent room
and/or a Passive Heat kit which disperses the heat into
the same room as the fireplace.
Refer to Section 6 of the appliance installation manual to
confirm which of the heat management systems may be
installed together. All heat management systems
must
be installed by a qualified service technician at the time of
appliance installation.
Optional Heat Management Systems
A fan is available for use with the B41L-AU appliance and
must be used in conjunction with the remote control.
Optional Fan Kit