29
29
3-90-30007480
Hearth and Home Technolgies • Oxford Direct/Natural Vent Installation Manual_R3 • 02/19
Figure 5.1
- Wiring Diagram
E. IPI Wiring Requirements
Intellifire™ Pilot Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 5.1, IPI Wiring Diagram.
• This appliance is equipped with an Intellifire™ Pilot
control valve which operates on a 3-Volt system.
• Plug the 3-Volt transformer plug into the appliance
junction box to supply power to the unit OR install (2) D
cell batteries (not included) into the battery pack before
use.
NOTICE:
Batteries should only be used as a power source in
the event of an emergency power outage. Batteries should
not be used as a primary long-term power source. Battery
polarity must be correct when installing batteries. When
using batteries as a power source, the 3-Volt transformer
must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 3-Volt transformer connected
to permanent electrical service.
Accessories Requirements
• Wiring for optional Hearth & Home Technologies
approved accessories should be done now to avoid
reconstruction. Follow instructions that come with those
accessories.
3V
Adapter
GRN
ORG
BLK
ORG
BLK
BRN
RED
BLK
Valve
WHT
Battery
Pack
To
Junction
Box
Control
Box
Flame
Sensor
Ignitor
Pilot Assembly
Wall Switch
+
- +
-