19
07/22
7027-804H
Outside Air through Rear
Wall (Horizontal)
NOTE; Use non-combustible
materials around exhaust vent
pipe and seal all edges with
non-flammable insulation such
as mineral wool or ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent furture
serviceability.
Figure 19.1
C. Full Reline With Outside Air - Horizontal
NOTE:
In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to
CAN/CSA-B365
.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual
design preference.
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in
good condition.
• Meets minimum standard of
NFPA 211
• Factory-built chimney must be a minimum
6 inch (152mm)
UL103 HT
.
WARNING