H. Inspect the Appliance and Components
• Remove the contents from the burner box. Attached to
the burner are tags identifying the manufacturer name,
serial number, model number (including gas log size),
BTU ratings, gas type, etc.
• Review the attached tags before proceeding. Ensure
that all minimum fireplace dimension requirements are
achieved using Table 3 . See Figure 1. Ensure the gas
type provided in the fireplace coincide with the gas type
marked on the tag.
Figure 2
Valve Cover (Safety Pilot)
Figure 1
Measure Firebox
• The burner is assembled with the controls installed at the
factory and is designed to connect one end of the 3/8 in.
supply line before placing inside the fireplace. Ensure the
connection is tightened using a 3/4 in. wrench.
• Place the burner towards the rear and center of the
fireplace and connect to the gas line. Follow instructions
in “F. Gas Pressure” to check for gas leaks.
• During shipping and handling of this appliance the safety
pilot control valve cover may not be in place. Once
the burner is installed in the fireplace, be sure to place
the cover over the valve to prevent overheating. See
Figure 2.
• IPI models include a battery box which holds 2 “D” size
batteries. The battery box should be placed in the right
front corner of your fireplace and covered with the log
cover as shown in Figure 3.
Figure 3A Control Box for IPI
Figure 3
Battery Box and Cover (for IPI units only)
• An On/Off switch is provided as part of the assembly. It
is located on the front right side of the burner assembly
as shown in Figure 3A.
• Optional remote control system can be incorporated
with this system by connecting the remote system to the
connection wires shown in Figure 3A.
• For propane (LP) installations skip to “J for Propane Gas
Installation”.
Battery Box
Optional Remote
Connection
On/Off Switch
Battery Box Cover