Hearthstone Quality Home Heating Products, Inc
® Green Mountain 40 (Model 8640)
9
C
OMBUSTIBLE
S
URFACE
R
EQUIRED
C
LEARANCES
Note: Dimensions shown in the following figures are from the body of the stove unless otherwise indicated.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and
ceilings when installing the stove near combustible surfaces.
Figure 4 – Clearance to Combustibles
Parallel
Corner
Corner
Clearances
A
B
C
D
E
F
Single wall Connector –
Inc. Rear Heat Shield
13”-33cm 9”-23cm 14”-36cm 24.5”-63cm 6”-16cm 16.5”-42cm
Single Wall Connector –
With Blower Kit Shield
13”-33cm 9”-23cm 14”-36cm 24.5”-63cm 6”-16cm
16.5”-42cm
Double Wall Connector –
Inc. Rear Heat Shield
13”-33cm 7”-18cm 12”-32cm 24.5”-64cm
6”-16cm
16.5”-42cm
Double Wall Connector –
With Blower Kit Shield
13”-33cm 7”-18cm 12”-32cm 24.5”-64cm
6”-16cm
16.5”-42cm
Alcove W/Single Wall Conn –
Inc. Rear Heat Shield
13”-33cm 9”-23cm 14”-36cm 24.5”-63cm 6”-16cm
16.5”-42cm
Alcove W/Single Wall Conn –
With Blower Kit Shield
13”-33cm 9”-23cm 14”-36cm 24.5”-63cm 6”-16cm
16.5”-42cm
Alcove W/Dbl Wall Conn –
Inc. Rear Heat Shield
13”-33cm 9”-23cm 14”-35cm 24.5”-61cm 6”-16cm
16.5”-42cm
Alcove W/Dbl Wall Conn –
With Blower Kit Shield
13”-33cm 9”-23cm 14”-35cm 24.5”-61cm 6”-16cm
16.5”-42cm
Alcove Clearances (inches)
Unprotected Surfaces Protected Surfaces (NFPA-211)
Minimum alcove width
50” – 157.5cm
See NFPA-211
Min. Alcove ceiling from floor with single wall connector 56” – 142.3cm
See NFPA-211
Min. Alcove ceiling from floor with double wall connector 56” – 142.3cm
See NFPA-211
FOR BLOWER KIT, USE KIT #96-57400