Hearthstone Quality Home Heating Products, Inc.
Bristol DX Model 8763
34
Designated Low Fire and High Fire
▪
Double-click small flame button.
"LO" will be displayed.
NOTE: Flame goes to high fire
first before going to designated
low fire.
▪
Double-click large flame button.
Flame automatically goes to
high fire. "HI" will be displayed
small flame button. "LO" will be
displayed.
TURNING FRONT BURNER ON/OFF (ONLY on
Waitsfield 8770)
NOTE: The latching solenoid valve cannot operate
manually. If the battery runs down it will remain in the
last operating position. During normal operation the
solenoid valve will be reset to the ON position when
the GV60 is switched OFF remotely.
WARNING
If the appliance will not operate, follow the instructions
"
TO SHUT DOWN THE APPLAINCE AND TURN
OFF GAS
” on page 27.
• Upon ignition Front and
Rear are ON.
• Simultaneously press
SET
and small flame buttons to
switch the Front burner
OFF. Printed instructions
are on the battery cover
(see Figure 43).
• Simultaneously press
SET
and large flame buttons to
switch Front burner ON.
(The AUX symbol on the
display indicates the
solenoid valve is OPEN)
NOTE: The operation of the
burner control valve is blocked in
timer OFF mode, when the
setting of the Nighttime setback
Temp (moon icon) is "_ _''.
Figure 43
– Aux Burner Control Instructions
LIGHT/DIMMER OPERATION
(
Not Applicable to Bristol, Waitsfield, Stowe or
Champlain)
• Briefly press
SET
button to
scroll to light bulb icon. Light
bulb icon flashes.
• Press and hold large flame
button to turn ON the light or
increase brightness.
• Press and hold small flame
button to decrease
brightness.
•
In the Light/Dimmer mode
the
OFF button shuts OFF the
light.
• If you want the light ON but no flame, press and
hold the small flame button and turn to Pilot flame.
NOTE: The light bulb icon is displayed during
light/dimmer setting only. 8 seconds after the
light/dimmer has been set, the handset
will
automatically go into temperature control mode (CSA
version)or manual mode (CE version).
CIRCULATING FAN OPERATION
(ONLY on Bristol 8763 and Waitsfield 8770)
The circulating fan has 4 speed
levels from low (1 bar) to high (4
bars).
▪
Briefly press
SET
button to
scroll to the fan icon. Fan
and Level icons flash.
▪
Press large flame button to
switch ON and increase fan
speed.