During  the  first  few  hours  of  operation  the  applianc e 
may produce  smoke and/or  odor.  This is normal  during 
the first several  burns and also after long periods  when 
the  stove  is  not  burned.  During  these  initial  burns,  
open  a  window(s)  to  assist  in  the  removal  of  the 
smoke/odor. 

 

The  appliance  and  its individual  shutoff  valve  must be 
disconnected  from  the  gas  supply  piping  system 
during  any  pressure  testing  of  that  system  at  test 
pressures  in  excess  of  ½  psig.  (3.5k  Pa).  The 
appliance  must be  isolated from  the gas supply piping 
system by  closing  its individual  manual  shutoff  valve 
during  any  pressure  testing  of  the  gas  supply  piping 
system at test pressures  equal  to  or  less than  ½  psig 
(3.5k Pa). 

 

Fire Hazard 

Do  not  store  or  use  gasoline  or  other  flammable 
vapors  or liquids in the vicinity of this appliance.  Locate 
the Bristol out of  traffic  areas  and  away  from  furniture,  
draperies,  clothing, and  flammable  material. 
 

Vent Only to the Outside 

Never  vent  the gas heater  to other  rooms or  buildings.  
 

Service Caution 

If  you  believe  your  Bristol  is  not,  in  any  way, 
performing 

properly, 

immediately 

discontinue 

operation  until  the  unit  is  inspected  and  approved  by 
qualified  service  personnel.   Prior to servicing  the unit, 
turn  the  gas  to  the  valve  off,  and  disconnect  any  
electrical  source.  Ensure  the  unit  is  cool  prior  to 
servicing  and  cleaning.  Replace  any  safety  screen,  
guard,  or component  removed  during  servicing  prior  to 
operation.  Use  of  any  components  not  supplied  by 
Hearthstone  on the  stove  voids  all  warranties. 

Do not 

substitute  components. 
 

Proper Fuel 

This  gas  heater  is designed  to  burn  natural  gas  (NG) 
or  with  conversion,  liquid  propane  (LP).  Never  burn 
any  fuel  gas  not intended  for  use  with this unit. Never 
burn  paper,  wood,  or other  materials  in this appliance.  

This  heater  is  factory  equipped  to  burn  natural  gas  
(NG).  To  burn  propane  (LP),  you  must  install  the 
included  LP conversion  kit #97-56631. 

This  appliance  is only  for  use  with  the  type(s)  of  gas  
indicated  on  the  rating  plate.  This  appliance  is  not  
convertible  for  use  with other  gases, unless a certified 
kit  is  used.

  Cet  appareil  doit  être  atilisé  uniquement  

avec  les  types  de  gas  indiqués  sur  la  plaque 
signalétique. Ne pas l’utiliser avec d’autres  gas sauf si 
un  k ited conversion  certifié est installé. ) 

 

WARNING:  THIS  GAS  APPLIANCE  MUST  NOT  BE 
CONNECTED  TO  A  CHIMNEY  FLUE  SERVING  A 
SEPARATE 

GAS 

OR 

SOLID-FUEL 

BURNING 

APPLIANCE 

 

WARNING:    DO  NOT  OPERATE  THE  APPLIANCE 
WITH  THE  FRONT  GLASS  REMOVED,  CRACKED, 
OR BROKEN.   REPLACEMENT  OF  GLASS  SHOULD 
BE  DONE  BY  A LICENSED  OR QUALIFIED  SERVICE 
PERSON.    ONLY  OPEN  FRONT  FOR  ROUTINE 
SERVICE.    DO  NOT  SLAM    FRONT  OR  STRIKE 
GLASS.  USE MANUFACTURER-APPROVED  FRONT 
GLASS  ONLY.

 

 

WARNING:  HEARTHSTONE  RECOMMENDS  THAT 
ONLY  AN  NFI  CERTIFIED  SERVICE  TECHNICIA N 
INSTALLS,  AND  REPAIRS  THIS  APPLIANCE.  A 
QUALIFIED  SERVICE  TECHNICIAN  MUST  INSPECT 
THE  APPLIANCE  BEFORE  USE,  AND  AT  LEAST 
ANNUALLY.  MORE  FREQUENT  CLEANING  MAY  BE 
REQUIRED 

DUE  TO  EXCESSIVE 

LINT  FROM 

CARPETING,  BEDDING  MATERIAL,  PETS,  ETC.  IT 
IS 

IMPERATIVE 

THAT 

THE 

CONTROL 

COMPARTMENTS,  BURNERS,  AND  CIRCULATI N G 
AIR  PASSAGES  OF  THE  APPLIANCE  ARE  KEPT 
CLEAN 

AND 

FREE 

OF 

OBSTRUCTIONS. 

(S’ASSURER 

QUE 

LE 

BRÛLEUR 

ET 

LE 

COMPARTIMENT 

DES 

COMMANDES 

SONT 

PROPRES. 

 

VOIR 

LES 

INSTRUCTIONS 

D’INSTALLATION 

ET 

D’UTILISATION 

QUI 

ACCOMPAGNENT L’APPAREIL.) 
 

Hot Surfaces 

Certain  exposed  surfaces  of  the Bristol will reach  high 
temperatures  during  normal  operation.   Clearances  to 
combustibles  must  be  maintained,  as  specified  in the 
“Clearances  To Combustibles”  section of this manual.   
 

 

DUE  TO  HIGH  TEMPERATURES  THE  APPLIANCE 
SHOULD  BE  LOCATED  OUT  OF  TRAFFIC  AND 
AWAY  FROM  FURNITURE,  DRAPERIES,  CLOTHING 
AND  FLAMMABLE  MATERIALS.    EN  RAISON DES 
TEMPÉRATURES ÉLEVÉES, L’APPAREIL DEVRAIT 
ÊTRE INSTALLÉ DANS UN ENDROIT OÙ IL Y A PEU 
DE CIRCULATION  ET  LOIN  DU MOBILIER  ET  DES 
TENTURES 

 

CHILDREN  AND ADULTS  SHOULD  BE ALERTED  TO 
THE 

HAZARDS 

OF 

HIGH 

SURFACE 

TEMPERATURES  AND  SHOULD  STAY  AWAY  TO 
AVOID  BURNS  TO  SKIN  OR  CLOTHING  IGNITION. 
LES ENFANTS ET LES ADULTES DEVRAIENT ÊTRE 
INFORMÉS  DES  DANGERS  QUE  POSENT  LES 
TEMPÉRATURES  DE  SURFACE  ÉLEVÉES  ET  SE 
TENIR 

À 

DISTANCE 

AFIN 

D’ÉVITER  DES 

BRÛLURES  OU  QUE  LEURS  VÊTEMENTS  NE 
S’ENFLAMMENT.
 

 

CAREFULLY 

SUPERVISE 

YOUNG 

CHILDREN 

WHEN  THEY  ARE  IN  THE  SAME  ROOM  AS  THE 
APPLIANCE.  TODDLERS,  YOUNG  CHILDREN,  AND 
OTHERS  MAY  BE  SUSCEPTIBLE  TO  ACCIDENT AL 
CONTACT 

BURNS.

 

BARRIERS 

DESIGNED 

TO 

Summary of Contents for 8763)

Page 1: ...un interrupteur Ne pas vous servir des t l phones se trouvant dans le batiment o vous vous trouvez Quittez le b timent imm diatement Appelez imm diatement votre fournisseur de gaz depuis un voisin Sui...

Page 2: ...ion 14 Electrical System Information 18 Gas Supply Connections 19 Gas Connections 19 Initial Leak Check 20 Pre Ignition Checks 20 Initial Lighting Instructions 22 Pilot Adjustment 23 Outlet Pressure A...

Page 3: ...lifting slightly and pulling forward free of the stove Set panel aside on a soft surface Locate and grasp receiver body Pull receiver straight forward from the mounting bracket firmly but slowly As so...

Page 4: ...safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail Website...

Page 5: ...Street Room 1511 Boston Massachusetts 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Bristol...

Page 6: ...ote control Part Description 8763 0010 Matte Black 8763 0020 Brown Enamel 8763 0030 Basil Enamel Read this Owner s Manual Operate and maintain this gas heater according to the instructions in this man...

Page 7: ...use with other gases unless a certified kit is used Cet appareil doit tre atilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un ki...

Page 8: ...AND BEHIND THE UNIT ON A REGULAR BASIS TO PREVENT THE ACCUMULATION OF DUST AND LINT Ceramic Logs Burner Baffle If the decorative ceramic log or burner material supplied with the Bristol is damaged or...

Page 9: ...is equipped for use at 0 to 2000 feet 0 610 meters altitude Cet appareil est equip pour des altitudes compries entre 0 et 2000 pieds 0 610 m seulement Items Required for Installation External regulat...

Page 10: ...let taking care to avoid damaging components mounted under the stove INSTALLER Leave this manual with the appliance INSTALLATEUR Laissez cette notice avec l appareil CONSUMER Retain this manual for fu...

Page 11: ...ntrol valve access door on the front of the unit as well as full access for periodic cleaning and servicing Also consider clearance for the blower assembly if present or planned in the future CAUTION...

Page 12: ...odate your installation CAUTION ENSURE ALL STOVE AND TERMINATION CAP CLEARANCES ARE OBSERVED PER THIS OWNER S MANUAL CAUTION ENSURE THERE IS NO WIRING OR PLUMBING IN THE CHOSEN LOCATION CAUTION DO NOT...

Page 13: ...1 2 13 12 to 16 12 6 1 8 17 12 to 21 12 8 2 4 Figure 8 Termination Cap clearances Prefabricated Fireplace Chimney Installations The Bristol 8763 is approved for use with direct vent chimney conversion...

Page 14: ...shion 2 Move the stove and pipe assembly back until the 90 elbow is flush to the wall The 24 vertical pipe should be parallel to the wall Draw a circle around the pipe Use the center of this circle as...

Page 15: ...eft and right side inlets 4 Position the restrictor plates over the intake openings by resting them on the firebox bottom and sliding them left or right until the screw hole in the restrictor plate al...

Page 16: ...e top of the stove from the outside before venting is attached by the following method 1 Note the two tabs extending into the inner flue collar from the upper manifold housing 2 Place the restrictor r...

Page 17: ...m CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center...

Page 18: ...Hearthstone Quality Home Heating Products Inc Bristol Model 8763 17 Figure 12 Venting Termination...

Page 19: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Page 20: ...INSTALLATION CAN CGA B149 NFPA Code and Hearthstone require the use of a dedicated sediment trap just upstream of the unit Damage to the valve or other components due to the lack of a sediment trap ar...

Page 21: ...ak detection method around the diaphragm flanges pipe connections seal cap and all other joints Bubbles indicate a leak 2 If no leakage is detected proceed with the instructions listed on page 20 to l...

Page 22: ...s placed in the appliance the surrounding metal can reduce reception considerably The position of the antenna on the receiver also influences reception NOTICE The antenna must not cross or come into c...

Page 23: ...et on a non marring surface 4 Locate and turn the MANUAL Knob on the valve clockwise to the MAN position see Figure 16 5 Turn the Main Valve knob to OFF 6 Using a pen or other device that will reach t...

Page 24: ...ent screw to set required burner pressure high fire Pressure is increased by turning clockwise pressure regulator models or decreased by turning counter clockwise 4 After adjustment replace the plug 5...

Page 25: ...pulling away from the screw head 3 Flip the conversion plug 1800 4 Slide the conversion plug back on the pressure screw shaft and gently push until is clicks in place 5 Reinstall the screw assembly u...

Page 26: ...Model 8763 25 Figure 20 Low Flow Orifice Location Figure 21 Low Flow Orifice Removal Figure 22 Low Flow Orifice Removal O ring Figure 23 NG Low Flow Screw Removal Figure 24 Press LP Orifice into Valve...

Page 27: ...the front of the pilot tower and the letters NAT should be visible on the upper horizontal surface see Figure 26 Slide the gate backward in the Pilot Tower by pushing on the upturned edge by the NAT l...

Page 28: ...ff position Manual Mode 1 Remove valve access panel 2 Turn the Main Valve Knob clockwise to OFF 3 Turn the ON OFF switch on the valve to OFF 4 Replace valve access panel 5 Turn the gas supply valve to...

Page 29: ...er with the narrow end resting on log 1as shown Figure 32 Log 2 in Position 4 Place log 3 as shown Figure 33 Log 3 in Position 5 Place log 4 on top of log 1 as shown Figure 34 Log 4 in Position 6 Plac...

Page 30: ...ed shutter results in a more yellow flame but too little air will result in incomplete combustion low efficiency and a dirty burn There are two simple guidelines to aid in determining the correct flam...

Page 31: ...igure 12 on page 17 for settings Restrictor Plate Adjustment Loosen the screw and position the restrictor plate in the desired location Tighten the screw to lock in place Figure 38 Restrictor Fully Cl...

Page 32: ...ination control 32oF to 176oF 0oC to 80oC Latching solenoid valve 32oF to 176oF 0oC to 80oC Receiver RF without batteries 176OF 80oC Receiver RF with batteries 131oF 55 C Receiver infrared with withou...

Page 33: ...8 5 Turn the Main Valve knob to OFF 6 Using a pen or other device that will reach through the MANUAL Knob cutout gently press the pilot button and hold it in the down position 7 After a ten second wai...

Page 34: ...es turn the main valve knob to OFF and follow the instructions TO SHUT DOWN THE APPLAINCE AND TURN OFF GAS on page 27 STANDBY MODE Pilot Flame Handset Press and hold small flame to set appliance at pi...

Page 35: ...Front burner ON The AUX symbol on the display indicates the solenoid valve is OPEN NOTE The operation of the burner control valve is blocked in timer OFF mode when the setting of the Nighttime setbac...

Page 36: ...Appliance must be in standby mode pilot ignited The room temperature is measured and compared to the set temperature The flame height is then automatically adjusted to achieve the Daytime Set Tempera...

Page 37: ...scroll to TEMP mode sun icon Hold the SET button until the set temperature on the screen flashes Press large flame button to increase Daytime Set Temperature Press small flame button to decrease Dayt...

Page 38: ...time P1 and moon is displayed and the time flashes Set the hour by pressing the large flame button Set the minutes by pressing the small flame button Setting P2 ON Time Once P1 times are set briefly p...

Page 39: ...d prior to operating the appliance Tout cran ou protecteur retir pour permettre l entretien de l appareil doit tre remis en place avant de mettre l appareil en marche Cleaning WARNING DO NOT CLEAN THE...

Page 40: ...G DISCONNECT POWER TO THE UNIT AND SHUT OFF THE GAS SUPPLY TO THE VALVE BEFORE REPLACING ANY BATTERIES Hearthstone recommends replacing all batteries at least very season Keep a supply of good quality...

Page 41: ...e four 1 8 rivets on the upper glass clips Push the top of the glass slightly away from the frame and lift it up above the lower clips and then out of the frame set it aside 7 Remove the glass from th...

Page 42: ...clips on the front glass frame The glass assemblies are now ready to remount on the unit If replacing entire glass with kit 1 Follow instructions included in glass kit Steps 1 11 under If Replacing Gl...

Page 43: ...t 3160 228 Flue Exhaust Gasket Kits 3160 152 Pilot Gasket 97 66630 Log Set 3160 712 Heat Exchanger Gasket 97 58621 Side Glass Assembly 3160 710 Delayed Ignition Relief Gasket Top 97 58620 Front Glass...

Page 44: ...after carefully following lighting instructions A Low or too high gas pressure B Faulty connections C Pilot dirty or plugged D Thermocouple damaged E Thermocouple Interrupter circuit damaged A Check f...

Page 45: ...may be too restrictive or blocked the rate at which the exhaust leaves draft determines the rate at which the combustion air is delivered Poor draft results in insufficientair delivery or a restricte...

Page 46: ...Hearthstone Quality Home Heating Products Inc Bristol DX Model 8763 45 Rating Label...

Page 47: ...ng the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or one year whichever is longer...

Page 48: ...baffles refractory materials ash grates and glass 4 Damage resulting from installation modification alteration repair or service of the appliance by any party other than an authorized Hearthstone dea...

Page 49: ...epair or to schedule a Dealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site www hearthstonestoves com if the original dealer...

Reviews: