Hearthstone Quality Home Heating Products, Inc
CHAMPLAIN DV Model 8301
A
CCEPTABLE
D
IRECT
-V
ENT
T
ERMINATION
C
AP
R
OOF
L
OCATIONS
The vent/air intake termination clearances above the
high side of an angled roof as follows:
Roof Pitch
Feet
Meters
Flat to 6/12
1
0.3
7/12 to 9/12
2
0.6
10/12 to 12/12
4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12
8
2.4
Figure 9: Termination Cap clearances
A
PPROVED
V
ENTING
S
YSTEM
C
OMPONENTS
(The following are components that are available, BUT NOT
necessary for all installations)
90
0
Elbow
Vertical Vent Cap
45
0
Elbow
36” Snorkel
6" Straight
9" Straight (Simpson only)
Vinyl Siding Standoff 4” x
6 5/8"
12" Straight
Round Ceiling Support
24" Straight
Thimble Covers
36" Straight
Wall thimble
48" Straight
Horizontal Vent Cap
11"-14 5/8" Adjustable
Pipe
C
HIMNEY
L
INER
S
YSTEM
Direct-Vent Chimney Liner Termination Kit
Chimney Liner Flex
Co-Linear Flex Connector
-Axial to Co-Linear Appliance Connect (Masonry
approved, not to exceed 16’ measured from the stove
top)
7. If the vent system is disassembled for any
reason, it must be reinstalled per the
instructions provided for in the initial
installation or in this manual.
V
ENT
C
ONFIGURATION
O
PTIONS
I.
S
TANDARD
H
ORIZONTAL
I
NSTALLATION
Kit #93-65000)
8.
Note:
Install the 45º elbow over the outer collar.
Place the elbow so that the twist lock end is
pointing straight up. Install the 2’ pipe section
into this elbow by fully inserting it, and turning
approximately ¼ turn clockwise until the two
sections are fully locked. Install the 90º elbow in
similar fashion with the opening pointing to the
rear.
9.
Note:
Ensure there is no Wiring or Plumbing in
the chosen wall location.
Move the stove and pipe assembly back until the 90º
elbow is flush to the wall. Ensure the 2’ vertical pipe
is still parallel to the wall. Draw a circle around the
pipe where it touches the wall. Use the center of
this circle as the center point of the 10”
x
10” square
wall pass through.
Cut and frame the wall for the vent pipe.
Install the
horizontal vent termination on the outside of the wall.
Ensure both of the retaining straps extend through
the wall pass through to the inside of the wall.
Before attaching the vent termination to the outside
of the house, run a bead of non-hardening mastic
around the outside edges, between the vent
termination and the wall. The arrow on the end cap
should point up. Secure the cap to the wall with the
appropriate screws.
Put the adjustable (11”-14”) pipe into the horizontal
vent cap, (the vent pipe must extend into the
horizontal vent cap a minimum of 1 ¼”). Move the
stove and vent pipe into position, insert the
adjustable (11”-14”) pipe into the 90° elbow, twist
lock it.
Secure the straps from the horizontal vent
termination to the interior pipe with two sheet metal
Page 13 of 30