Hearthstone Quality Home Heating Products, Inc
CHAMPLAIN DV Model 8301
Page 14 of 30
screws, keeping the screws as close to the wall
thimble as possible. Bend or cut the excess
strapping so the thimble cover will fit properly.
Screw the thimble cover to the wall.
The adjustment range for wall thickness for
this configuration is 3”min to 9”max.
II.
F
IREPLACE
V
ENTING
I
NSTALLATIONS
-40' maximum system height (without offsets)
-14' maximum offset
(refer to Figures 10 - 12)
-Maximum rise to run = 1 to 5
(refer to Figures 9-
13)
-
The termination must meet the requirements
outlined in
Figure 8
and
Figure 9.
Figure 10: Vertical Venting Rules
III.
V
ERTICAL
T
ERMINATION
V
ENTING
C
ONFIGURATIONS
-40' maximum system height (without offsets)
Figure 11: Approved DV Vertical Co-Axial Termination Configurations