PECIFICATIONS
Testing Agency:
Intertek Testing Services NA, Inc.
(ITS)
Listed:
Direct Vent Gas Heater
Model:
Champlain DV Model 8301
Tested to:
ANSI Z21.88b – 2008/CSA 2.33b - 2008
Certified for Canada, CSA P.4.1
Approved for Mobile Home Installation
Certified for use by:
Board of State Examiners of Plumbers and Gasfitters
100 Cambridge Street, Room 1511
Boston, Massachusetts 02202
Manufactured and Warranted by:
Hearthstone Quality Home Heating Products, Inc.
317 Stafford Ave.
Morrisville, VT 05661-8695, USA
www.hearthstonestoves.com
Figure 1 – Champlain DV Dimensions
Specification NG
LP
Input rating (Btu/hr) 0-2000 ft
35,000
35,000
Input rating (Btu/hr) 2000-4500 ft
35,000
33,300
Orifice size DMS 0-2000 ft
32
49
Orifice size DMS 2000-4500 ft
32
50
Man. press.-LO setting (in.w.c./kPa) 1.2/0.3
3.3/0.8
Man. press.-HI setting (in.w.c./kPa)
3.5/0.87
10.0/2.48
Inlet press.-LO setting(in.w.c./kPa)
5.0/1.24
11.0/2.88
Inlet press.-HI setting(in.w.c./kPa)
7.0/1.74
13.0/3.22
Minimum input rating rating (Btu/hr)
21,500
20,400
Maximum output (Btu/hr) 0-2000 ft
25,600
25,600
Page 5 of 30