background image

Hearthstone Quality Home Heating Products, Inc                                                                 

             CHAMPLAIN DV Model 8301  

O

WNER

I

NFORMATION

 

 

The installation must conform with local codes or, in 
the absences of local codes, the current National 
Fuel Gas Code, ANSI Z223.1 (NFPA 54), or 
CAN/CGA B149 Installation Code. 

(Installer 

l’appareil selon les codes ou règlements locaux, ou, 
en l’absence de tels règlements, selon les Codes 
d’installation CAN/CGA-B149.)  

Service Caution 

Replace any components of the stove removed for 
servicing before operating. If you believe your 
Champlain is not performing properly, immediately 
discontinue operation until the unit is inspected and 
approved for operation by qualified service 
personnel. Prior to servicing the unit, turn the gas 
supply to the valve off. Ensure the unit is cool before 
servicing and cleaning. 

Do not use any components other than those 
approved by Hearthstone Quality Home Heating 
Products, Inc., otherwise all warranties are void. 

Do 

not substitute components! 

F

IRE 

H

AZARD

 

Do not store, or use gasoline, or other flammable 
vapors or liquids near this appliance. The Champlain 
should be located out of traffic, and away from 
furniture, draperies, clothing, and other flammable 
materials. 

S

HOCK 

H

AZARD 

 

(If equipped with accessory blower)  The accessory 
blower is equipped with a three-prong (grounding) 
plug for protection against shock hazard and must 
be plugged directly into a properly grounded three-
prong receptacle.  Do not cut, or remove, the 
grounding prong from the plug. 

H

OT 

S

URFACES

 

Certain exposed surfaces of the Champlain will 
reach high temperatures during normal operation.  
Clearances to combustibles must be maintained, as 
specified in the “Clearances To Combustibles” 
section of this manual. Due to high temperatures, 
the appliance should be located out of traffic and 
away from furniture, draperies, clothing, and other 
flammable materials. Alert children and adults to the 
hazards of high surface temperatures and that they 
must stay away to avoid burns to skin or possible 
clothing ignition.  

Supervise young children carefully when in the same 
room as the appliance. Do not place clothing or 
other flammable material on or near the appliance. 

 

(Surveille les enfants.  Garder les vêtements, les 
meubles, l’essence ou autres liquides à vapeur 
inflammables lin de l’appareil.)

 

Clean the area around, under, and behind the unit 
on a regular basis to prevent the accumulation of 
dust and lint. 

 

WARNING! DO NOT OPERATE THIS APPLIANCE 
WITH THE FRONT GLASS REMOVED, CRACKED, 
OR BROKEN. REPLACEMENT OF GLASS 
SHOULD BE DONE BY A LICENSED OR 
QUALIFIED SERVICE PERSON. ONLY OPEN 
FRONT FOR ROUTINE SERVICE. DO NOT SLAM, 
OR STRIKE THE GLASS. 

 

WARNING! A QUALIFIED SERVICE TECHNICIAN 
SHOULD PERFORM THE INSTALLATION, AND 
ANY REPAIRS. A QUALIFIED SERVICE 
TECHNICIAN MUST INSPECT THE APPLIANCE 
BEFORE USE, AND AT LEAST ANNUALLY. MORE 
FREQUENT CLEANING MAY BE REQUIRED DUE 
TO EXCESSIVE LINT FROM CARPETING, 
BEDDING MATERIAL, PETS, ETC. IT IS 
IMPERATIVE THAT THE CONTROL 
COMPARTMENTS, BURNERS, AND CIRCULATING 
AIR PASSAGES OF THE APPLIANCE ARE KEPT 
CLEAN AND FREE OF OBSTRUCTIONS. 
(S’ASSURER QUE LE BRÛLEUR ET LE 
COMPARTIMENT DES COMMANDES SONT 
PROPRES.  VOIR LES INSTRUCTIONS 
D’INSTALLATION ET D’UTILISATION QUI 
ACCOMPAGNENT L’APPAREIL.)
 

 

 

Page 6 of 30 

Summary of Contents for Champlain 8301

Page 1: ...er service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a lic...

Page 2: ...Intentionally Blank Page 1 of 30...

Page 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 4: ...ON 9 CLEARANCES TO COMBUSTIBLES 9 HEARTH REQUIREMENT FLOOR PROTECTION 9 VENTING INFORMATION 11 VENTING COMPONENTS CONFIGURATION 11 VENT CONNECTION 11 ACCEPTABLE DIRECT VENT TERMINATION CAP ROOF LOCATI...

Page 5: ...MATERIAL PETS ETC IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGES OF THE APPLIANCE ARE KEPT CLEAN AND FREE OF OBSTRUCTIONS S ASSURER QUE LE BR LEUR ET LE COMPARTIME...

Page 6: ...Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Champlain DV Dimensions Specification NG LP Input rating Bt...

Page 7: ...of the Champlain will reach high temperatures during normal operation Clearances to combustibles must be maintained as specified in the Clearances To Combustibles section of this manual Due to high t...

Page 8: ...ontrol valve access door 10 Plug in the blower accessory if so equipped 11 Set thermostat to ON and set the desired temperature setting Normally if the T STAT position was selected the main burner is...

Page 9: ...st equip pour des altitudes compries entre 0 et 2000 pieds 0 610 m seulement UNPACKING AND INSPECTION Unpack and Inspect for Damage Hearthstone packages the Champlain to withstand normal shipment with...

Page 10: ...ve these two screws and replace them with the two decorative caps provided with the unit 6 To re install reverse the outlined steps above ITEMS REQUIRED FOR INSTALLATION External regulator for LP Phil...

Page 11: ...BY LOCAL CODES THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED AVAILABLE TH...

Page 12: ...her direction for installation please refer to the venting instructions provided with the venting components VENT CONNECTION The Champlain Direct Vent Model 8301 is approved for installation only with...

Page 13: ...recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center line of the regu...

Page 14: ...e elbow so that the twist lock end is pointing straight up Install the 2 pipe section into this elbow by fully inserting it and turning approximately turn clockwise until the two sections are fully lo...

Page 15: ...ll thickness for this configuration is 3 min to 9 max II FIREPLACE VENTING INSTALLATIONS 40 maximum system height without offsets 14 maximum offset refer to Figures 10 12 Maximum rise to run 1 to 5 re...

Page 16: ...to run 1 to 5 The termination must meet the requirements outlined in Figure 8 9 Use a vinyl siding Stand off when installing against vinyl siding Horizontal sections require a 1 4 rise every 12 of ho...

Page 17: ...8301 Figure 13 Venting Configuration and Restrictor Settings VENT RESTRICTOR To adjust your restrictor for maximum flame appearance loosen the phillips head screw and spin the locator found on the re...

Page 18: ...ressure and manifold gas pressure must be tested The gas control valve has built in pressure taps for test gauge connections The supply line pressure must be tested to ensure it meets the minimum pres...

Page 19: ...nd stove parts reduced efficiency and high levels of carbon monoxide If the log set does not fit into the firebox exactly as outlined contact your dealer for assistance INSTALLATION OF THE LOG SET CAU...

Page 20: ...e embers into the burner holes Locate and open the bag of Platinum Bright Embers Pull apart small pieces of the wool and sprinkle over the Charcoal Embers randomly This wool will glow brightly once th...

Page 21: ...r all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on the floor If you detect gas check for leaks WARNING...

Page 22: ...ONLY A QUALIFIED GAS TECHNICIAN SHOULD DO THE CONVERSION For checking and properly adjusting the manifold pressure refer to the Gas Connection section on page 17 of this manual Leak test before and af...

Page 23: ...he thermocouple and thermopile Turn the unit off by setting the switch to Off and turning off the gas control valve Allow the unit to cool Check and clean any burner ports that are not burning or not...

Page 24: ...ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMAN...

Page 25: ...TER 3160 157 GASKET 6 7211 221 BURNER ASSEMBLY 3160 300 PRIMARY AIR CONTROL GASKET 7211 430 IGNITER ELECTRODE 3170 150 PLATINUM BRIGHT EMBERS 7211 470 THERMOCOUPLE 5300 066 PIEZO BRACKET 7211 601 BOTT...

Page 26: ...3 57010 This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by l...

Page 27: ...embly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure A Check for proper inlet pressure for...

Page 28: ...er does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot a...

Page 29: ...f gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creating a roari...

Page 30: ...ed and signed Warranty Registration Form which is enclosed in the Gas Stove warranty packet to the following address Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Aven...

Reviews: