background image

Hearthstone Quality Home Heating Products, Inc                                                                 

             CHAMPLAIN DV Model 8301  

I

NSTALLER

I

NFORMATION

C

ODES

 

Adhere to 

all

 

local codes

 or, in their absence, 

obtain the latest edition of THE NATIONAL FUEL 
GAS CODE ANSI Z223.1 (NFPA 54) or CAN/CGA 
B149 Installation Code from: 

AMERICAN NATIONAL STANDARDS INSTITUTE, INC.

 

1430 BROADWAY 
NEW YORK, NY 10018 
www.ansi.org

 

OR 

NATIONAL FIRE PROTECTION ASSOCIATION, INC.

 

BATTERY MARCH PARK 
QUINCY, MA 02269 
www.nfpa.org

 

The appliance, when installed with a blower, must 
be electrically connected and grounded in 
accordance with local codes or, in the absence of 
local codes, with the current NFPA 70-National 
Electrical Code or CSA C22.1-Canadian Electric 
Code. 

A manufactured home (or mobile) OEM installation 
must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, 
Part 3280 (U.S.) or Standard for Manufactured 
Home Installation, ANSI/NCBCS A225.1 or Standard 
for Gas Equipped Recreational Vehicles and mobile 
Housing, CSA Z240.4.CAN/SCA Z240 MH 
(Canada).    

(Installer l’appareil selon les codes ou 

règlements locaux, ou, en l’absence de tels 
règlements, selon les Codes d’installation 
CAN/CGA-B149.)  

For installations from 610-1370 meters (2000-4500 
ft.) the orifice sizes (DMS) for natural and propane 
gas are 32 and 52 respectively.  See data plate for 
additional information.  For high altitude installations 
consult the local gas distributor or the authority 
having jurisdiction for proper rating methods.  If the 
installer must convert the unit to adjust for varying 
altitudes, the information sticker must be filled out by 
the installer and adhered to the appliance at the 
same time of conversion. 

(Cet appareil est equipè 

pour des altitudes compries entre 0 et 2000 pieds 
(0-610 m) seulement.)

  

U

NPACKING AND 

I

NSPECTION 

 

Unpack and Inspect for Damage

 

Hearthstone packages the Champlain to withstand 
normal shipment without damage. However, 
damage can still occur during transit, so take care to 
inspect for damage when unpacking and installing 

the unit. If you detect any damage, or a missing part,  
immediately contact your dealer.

  

 

Do not install or put into service a damaged 
or incomplete heater.

   

The unit should appear square and level, with the 
sheet metal parts smooth and free of bends or 
dents.  Enameled cast iron should be free of chips or 
cracks.  If you find visible or concealed damage, 
contact your dealer. 

P

ACKING 

L

IST

 

1-Champlain DV Gas-fired Heater containing: 

6-Decorative Fiber Logs 
1-Pan Burner 
1-Owner’s Manual and Warranty 
1-Bag Charcoal Embers 
1-Bag Platinum Bright Embers 
2-Decorative Caps 

1-Accessory box containing: 

1-Top Grille 
1-Thermostat with Thermostat Wire 
2-Extension control Knobs 
1-LP Conversion kit 

F

IBER 

L

OG 

S

AFETY 

I

NFORMATION

 

The decorative fiber logs supplied with the 
Champlain are located in the firebox.  Always use 
great care when handling the decorative fiber logs, 
as they are fragile and subject to damage and 
breakage.  If the decorative fiber logs supplied with 
the Champlain are damaged, they must be replaced. 
Contact your local Hearthstone dealer for 
replacement parts. Do not replace fiber logs, or the 
embers, with any materials not approved by 
Hearthstone. 

F

IREBOX 

A

CCESS

 

To open the firebox: 

1.  Remove the two upper front screws (located in 

the grill of the front) that hold the cast façade 
onto the unit. 

(These screws ship on the unit 

for transit purposes only and are removed 
during installation.)

  

2.  Open the valve access door by pulling the ash 

lip out off the magnet and down. Allow the door 
to swing down completely.  

Page 8 of 30 

Summary of Contents for Champlain 8301

Page 1: ...er service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a lic...

Page 2: ...Intentionally Blank Page 1 of 30...

Page 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 4: ...ON 9 CLEARANCES TO COMBUSTIBLES 9 HEARTH REQUIREMENT FLOOR PROTECTION 9 VENTING INFORMATION 11 VENTING COMPONENTS CONFIGURATION 11 VENT CONNECTION 11 ACCEPTABLE DIRECT VENT TERMINATION CAP ROOF LOCATI...

Page 5: ...MATERIAL PETS ETC IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGES OF THE APPLIANCE ARE KEPT CLEAN AND FREE OF OBSTRUCTIONS S ASSURER QUE LE BR LEUR ET LE COMPARTIME...

Page 6: ...Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Champlain DV Dimensions Specification NG LP Input rating Bt...

Page 7: ...of the Champlain will reach high temperatures during normal operation Clearances to combustibles must be maintained as specified in the Clearances To Combustibles section of this manual Due to high t...

Page 8: ...ontrol valve access door 10 Plug in the blower accessory if so equipped 11 Set thermostat to ON and set the desired temperature setting Normally if the T STAT position was selected the main burner is...

Page 9: ...st equip pour des altitudes compries entre 0 et 2000 pieds 0 610 m seulement UNPACKING AND INSPECTION Unpack and Inspect for Damage Hearthstone packages the Champlain to withstand normal shipment with...

Page 10: ...ve these two screws and replace them with the two decorative caps provided with the unit 6 To re install reverse the outlined steps above ITEMS REQUIRED FOR INSTALLATION External regulator for LP Phil...

Page 11: ...BY LOCAL CODES THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED AVAILABLE TH...

Page 12: ...her direction for installation please refer to the venting instructions provided with the venting components VENT CONNECTION The Champlain Direct Vent Model 8301 is approved for installation only with...

Page 13: ...recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center line of the regu...

Page 14: ...e elbow so that the twist lock end is pointing straight up Install the 2 pipe section into this elbow by fully inserting it and turning approximately turn clockwise until the two sections are fully lo...

Page 15: ...ll thickness for this configuration is 3 min to 9 max II FIREPLACE VENTING INSTALLATIONS 40 maximum system height without offsets 14 maximum offset refer to Figures 10 12 Maximum rise to run 1 to 5 re...

Page 16: ...to run 1 to 5 The termination must meet the requirements outlined in Figure 8 9 Use a vinyl siding Stand off when installing against vinyl siding Horizontal sections require a 1 4 rise every 12 of ho...

Page 17: ...8301 Figure 13 Venting Configuration and Restrictor Settings VENT RESTRICTOR To adjust your restrictor for maximum flame appearance loosen the phillips head screw and spin the locator found on the re...

Page 18: ...ressure and manifold gas pressure must be tested The gas control valve has built in pressure taps for test gauge connections The supply line pressure must be tested to ensure it meets the minimum pres...

Page 19: ...nd stove parts reduced efficiency and high levels of carbon monoxide If the log set does not fit into the firebox exactly as outlined contact your dealer for assistance INSTALLATION OF THE LOG SET CAU...

Page 20: ...e embers into the burner holes Locate and open the bag of Platinum Bright Embers Pull apart small pieces of the wool and sprinkle over the Charcoal Embers randomly This wool will glow brightly once th...

Page 21: ...r all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on the floor If you detect gas check for leaks WARNING...

Page 22: ...ONLY A QUALIFIED GAS TECHNICIAN SHOULD DO THE CONVERSION For checking and properly adjusting the manifold pressure refer to the Gas Connection section on page 17 of this manual Leak test before and af...

Page 23: ...he thermocouple and thermopile Turn the unit off by setting the switch to Off and turning off the gas control valve Allow the unit to cool Check and clean any burner ports that are not burning or not...

Page 24: ...ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMAN...

Page 25: ...TER 3160 157 GASKET 6 7211 221 BURNER ASSEMBLY 3160 300 PRIMARY AIR CONTROL GASKET 7211 430 IGNITER ELECTRODE 3170 150 PLATINUM BRIGHT EMBERS 7211 470 THERMOCOUPLE 5300 066 PIEZO BRACKET 7211 601 BOTT...

Page 26: ...3 57010 This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by l...

Page 27: ...embly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure A Check for proper inlet pressure for...

Page 28: ...er does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot a...

Page 29: ...f gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creating a roari...

Page 30: ...ed and signed Warranty Registration Form which is enclosed in the Gas Stove warranty packet to the following address Hearthstone Quality Home Heating Products Inc Warranty Department 317 Stafford Aven...