Hearthstone Quality Home Heating Products, Inc
CHAMPLAIN Model 8302
13
-Maximum rise to run = 1 to 5
(refer to Figures
10 -13)
-
The termination must meet the requirements
outlined in
Figures 7
-
9.
Figure 10: Vertical Venting Rules
III. Vertical Termination Venting
Configurations
-40' maximum system height (without offset)
IV.
H
ORIZONTAL
T
ERMINATION
V
ENTING
C
ONFIGURATIONS
•
A minimum of 24" rise is required (with or w/o
offsets)
•
40' maximum system height (without offsets)
•
Maximum rise to run = 1 to 5
•
The termination must meet the requirements
outlined in
Figures 7 - 9.
Use a vinyl siding
stand off when installing against vinyl siding.
•
Horizontal sections require a 1/4" rise every 12"
of horizontal run.
•
For each 90° elbow after the second, remove 5'
from horizontal run.
•
Use with snorkel termination 45" maximum
horizontal run
Figure 11: Approved DV Vertical Co-Axial
Termination Configurations
Summary of Contents for Champlain 8302