Hearthstone Quality Home Heating Products, Inc.
Stowe 3 Model 8323
22
gassing and fumes will subside after the first 8 hours
of operation.
Odors and Impurities
A heater of this type may produce odors during
heater operation at any time due to impurities that
may exist in the immediate area around the unit.
Sources of impurities can include cleaning solvents,
paint solvents, cigarettes, candles, smoke, pet hair,
dust, adhesives, new carpet, and/or textiles. Such
odors will eventually dissipate. However, opening a
window or otherwise providing additional ventilation
to the area can alleviate the condition sooner. If any
odor persists, find and remove the cause, or contact
your dealer or an authorized service technician.
Pilot Adjustment
CAUTION: THE PILOT FLAME SHOULD ONLY BE
ADJUSTED BY AN AUTHORIZED SERVICE
TECHNICIAN.
The pilot flow adjustment is preset to maximum at
the factory. The pilot flame should
envelope 3/8” to
1/2” of the thermocouple
(see figure 20).
To adjust pilot:
1. The adjustment screw can be reached through a
hole in the MANUAL knob
(see figure 21).
2. Turn the MANUAL knob to the ON position.
3. It is now possible to pierce through a film on the
cover with a screwdriver to reach the adjustment
screw beneath.
4. Turn the adjustment screw clockwise to
decrease or counter-clockwise to increase pilot
flame.
Controlling the Champlain manually or by the
optional remote become erratic, nonexistent, or the
unit may go out, if the pilot flame is too small or
misdirected away from the thermopile.
WARNING: THE CONTROL HAS AN INTERLOCK
DEVICE. IF THE STOVE HAS BEEN LIT, IT WILL
NOT RELIGHT AGAIN IMMEDIATELY. AFTER
SHUTTING OFF ALL GAS FLOW, THE PILOT
BURNER
CANNOT
BE
RELIT
UNTIL
THE
THERMOCOUPLE HAS COOLED (
60 SECONDS
TO 2 MINUTES)
.
Outlet Pressure Adjustment
CAUTION: THE VALVE MAXIMUM OUTLET
PRESSUE SHOULD ONLY BE ADJUSTED BY AN
AUTHORIZED SERVICE TECHNICIAN AND IS
PRE-SET AT THE FACTORY.
Figure 20 - Pilot Flame Pattern
1. Connect a pressure manometer to the valve
outlet pressure tap. Pressure tap is opened by
turning the screw counter-clockwise
(see figure
18).
2. Turn MANUAL knob and main valve knob to the
ON position.
3. Turn pressure regulator adjustment screw to set
required burner pressure (high fire). Pressure is
increased by turning clockwise. (pressure
regulator models), or decreased by turning
counter-clockwise.
4. After adjustment, replace the plug.
5. If no other adjustments are required, close
pressure tap(s) by turning the screw(s) fully
clockwise
until
snug.
Check
all
connections/pressure tap(s) for leaks.
6. If the desired outlet pressure or flow cannot be
achieved by adjusting the gas valve, check the
gas valve inlet pressure using a manometer at
the valve inlet pressure tap. If the inlet pressure
is in the normal range, replace the gas valve;
otherwise, take necessary steps to assure
proper gas pressure to the valve.
Minimum Gas Flow Adjustment
CAUTION: THE MINIMUM VALVE OUTLET
PRESSUrE SHOULD ONLY BE ADJUSTED BY AN
AUTHORIZED SERVICE TECHNICIAN AND IS
PRE-SET AT THE FACTORY.
a. Light the stove and engage the main burner.
Summary of Contents for Champlain 8302
Page 45: ...44 07044 2 RATING LABEL...