Hearthstone Quality Home Heating Products, Inc.
Stowe 3 Model 8323
25
Figure 27
– Tighten LP Low Flow Orifice
To Switch the Pilot to LP Operation:
(Refer to figures 28-31)
The pilot assembly in the Champlain 8302 is a slide
convertible unit, only requiring access from the
firebox and a 7/16” open-end wrench. To convert
pilot from NG to LP:
1. Follow steps listed in the Installation
Preparation section on pages 9 - 10 for
gaining access to the firebox and removing
the logs.
2.
Using the 7/16” wrench, grasp the pilot
tower and turn counter-clockwise about 1/4
turn
(see figure 29).
3. Look at the front edge of the base of the
pilot tower. You will see the NG/LP Pilot
Orifice Gate protruding toward the front of
the pilot tower and
the letters “NAT” should
be visible on the upper horizontal surface
(
see figure 28).
Slide the gate backward in
the Pilot Tower by pushing on the upturned
edge by the “NAT” lettering until the
upturned edge is flush with the Pilot Tower
surface. You will see the NG/LP Pilot Gate
protruding from the back edge of the Pilot
Tower and the letters “LP” will be visible,
separated by a punched hole.
4.
While holding the NG/LP Pilot Gate in the
LP visible position, grasp the Pilot Tower
with the 7/16” wrench and turn clockwise
until the tower is snug. The Pilot Hood
should be oriented such that one pilot flame
is directed at the thermocouple and the
other is facing the main burner
(see figure
31).
Figure 28
– Pilot in NG (Pilot Gate forward)
Figure 29
– Loosen Tower and Slide Pilot
Gate to Rear of Pilot Tower (LP position)
Summary of Contents for Champlain 8302