Hearthstone Quality Home Heating Products, Inc
CHAMPLAIN Model 8302
4
S
PECIFICATIONS
Testing Agency:
Intertek Testing Services NA, Inc.
(ITS)
Listed:
Direct Vent Gas Heater
Model:
Champlain Model 8302
Tested to:
ANSI Z21.88b
– 2014/CSA 2.33b - 2014
Certified for Canada, CSA P.4.1
Approved for Mobile Home Installation
Certified for use by:
Board of State Examiners of Plumbers and Gasfitters
100 Cambridge Street, Room 1511
Boston, Massachusetts 02202
Manufactured and Warranted by:
Hearthstone Quality Home Heating Products, Inc.
317 Stafford Ave.
Morrisville, VT 05661-8695, USA
www.hearthstonestoves.com
Figure
1 Champlain DV Dimensions
Specification
NG
LP
Input rating (Btu/hr) 0-2000 ft
35,000
35,000
Input rating (Btu/hr) 2000-4500 ft
35,000
35,000
Orifice size DMS 0-2000 ft
32
51
Orifice size DMS 2000-4500 ft
32
51
Man. press.-LO setting (in.w.c./kPa)
1.2/0.3
4.3/1.07
Man. press.-HI setting (in.w.c./kPa)
3.4/0.87
10.0/2.48
Minimum Inlet press.(in.w.c./kPa)
5.0/1.25
12.0/2.99
Minimum input rating rating (Btu/hr)
21,000
23,000
Summary of Contents for Champlain 8302
Page 45: ...44 07044 2 RATING LABEL...