background image

Hearthstone Quality Home Heating Products, Inc                                                                 

             CHAMPLAIN Model 8302  

 

Installation Preparation 

C

ODES

 

Adhere  to 

all

 

local  codes

  or,  in  their  absence, the 

latest edition of THE NATIONAL FUEL GAS CODE 
ANSI  Z223.1  (NFPA  54)  or  CAN/CGA  B149 

 

(Installer  l’appareil  selon  les  codes  ou  règlements 
locaux,  ou,  en  l’absence  de  tels  règlements,  selon 
les Codes d’installation CAN/CGA-B149.) 

Installation Codes can be obtained from:

 

AMERICAN NATIONAL STANDARDS 
INSTITUTE, INC.

 

1430 BROADWAY 
NEW YORK, NY 10018 
www.ansi.org 

NATIONAL FIRE PROTECTION 
ASSOCIATION, INC.

 

BATTERY MARCH PARK 
QUINCY, MA 02269 
www.nfpa.org 

The  appliance  when  installed  must  be  electrically 
connected  and  grounded  in  accordance  with  local 
codes  or,  in  the  absence  of  local  codes,  with  the 
current  NFPA  70-National  Electrical  Code  or  CSA 
C22.1-Canadian Electric Code. 

A  manufactured  home  (mobile)  OEM  installation 
must 

conform 

to 

the 

Manufactured 

Home 

Construction  and  Safety  Standard,  Title  24  CFR, 
Part  3280  (U.S.)  or  Standard  for  Manufactured 
Home 

Installation, 

ANSI/NCBCS 

A225.1 

or 

Standard  for  Gas  Equipped  Recreational  Vehicles 
and  mobile  Housing,  CSA  Z240.4.CAN/SCA  Z240 
MH  (Canada).  This  appliance  is  only  for  use  with 
the type(s) of gas indicated on the rating plate. 

Cet 

appareil  peut  être  installé  comme  du  matériel 
d’origine  dans  une  maison  préfabriquée  (É.-U. 
seulement)  ou  mobile  et  doit  être  installé  selon  les 
instructions  du  fabricant  et  conformément  à  la 
norme  Manufactured  Home  Construction  and 
Safety 
Standard,  Title  24  CFR,  Part  3280  aux  États-Unis 
ou  à  la  norme  CAN/CSA-Z240  Série  MM,  Maisons 
mobiles  au  Canada.  Cet  appareil  doit  être  utilisé 
uniquement  avec  les  types  de  gaz  indiqué  s  sur  la 
plaque signalétique. 

This appliance is equipped for use at 0 to 2000 feet 
(0-610  meters)  altitude. 

(Cet  appareil  est  equipè 

pour  des  altitudes  compries  entre  0  et  2000  pieds 
(0-610 m) seulement.)

  

Items Required for Installation 

  External regulator (for propane (LP) only) 
  LP conversion kit (for propane only)) 
  Piping which complies with local codes 

  Pipe sealant approved for use with                                

propane (LP) (resistant to sulfur compounds). 

  Manual shutoff valve 
  Sediment trap (

see page 20

  Pipe wrench 
  Phillips head screwdriver 
  7/16-inch wrench 
 

5/23” (4mm) allen wrench 

  Other parts as required by local code 
  Safety Glasses 
  Gloves 

 

Packing List 

1- Champlain 8302 Gas-Fired Heater 
1- Pan Burner 
1- 

Owner’s Packet (manual, warranty card) 

1- LP Conversion Kit 
6- Decorative Ceramic Logs (in separate box) 
1- Bag of Platinum Bright Embers 

 

 

Note:  Vent  kits  and  components  are  supplied 
separately. 

Failure 

to 

use 

the 

venting 

components  approved  by  Hearthstone  for  this 
appliance will void your warranty.

 

 

Unpacking and Inspection 

 

 

Hearthstone  packages  your  Champlain    to 
withstand  normal  shipment  without  damage. 
However,  damage  can  still  occur  during  transit. 
Take  care  to  inspect  for  damage  when  unpacking 
and installing the unit.    

 

DO  NOT  INSTALL,  OR  PUT  INTO  SERVICE,  A 
DAMAGED OR INCOMPLETE HEATER.

   

Remove  the  shrink-wrap  and  other  packaging 
materials  taking  care  not  to  damage  the  stove’s 
finish.  Inspect  the  Champlain  for  visible  or 
concealed damage. The unit should be square and 
true.  The  sheet  metal  parts  should  be  smooth  and 
free  of  bends  and  dents.  Any  enameled  cast  iron 
should  be  free  of  chips  or  cracks.  If  visible  or 
concealed  damage  is  found  or  suspected,  contact 
your dealer for instructions. 

Always  use  gloves  and  eye  protection  when 
handling  the  decorative  ceramic  fire  logs  and 
burner. Use care when handling these parts as they 
are  fragile  and  subject  to  damage  and  breakage  if 
handled roughly.  
See  the  firebox  access  instructions  on  page  9. 
Unpack  and  inspect  the  logs  for  damage.  Inspect 
the metal burner as well. Open the other boxes and 
inspect  the components.  If log, burner  or any  other 
component  damage  is  encountered,  contact  your 
dealer  for  a  replacement.  Otherwise,  set  the  logs 

Summary of Contents for Champlain 8302

Page 1: ...service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licen...

Page 2: ...pply Connections 18 Gas Connections 19 Initial Leak Check 19 Pre Ignition Checks 19 Initial Lighting Instructions 21 Remote Ignition Instructions 21 Manual Ignition Instructions 21 Pilot Adjustment 22...

Page 3: ...nt lip lifting slightly and pulling forward free of the stove Set panel aside on a soft surface Locate and grasp receiver body Pull receiver straight forward from the mounting bracket firmly but slowl...

Page 4: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 5: ...Room 1511 Boston Massachusetts 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Cham...

Page 6: ...tter on remote control Part Description 8302 0010NP Matte Black 8302 0020NP Brown Enamel Read this Owner s Manual Operate and maintain this gas heater according to the instructions in this manual For...

Page 7: ...on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit tre atilis uniquement avec les types de gas indiqu s sur la plaque sign...

Page 8: ...burner material supplied with the Champlain is damaged or parts are missing they must be replaced with the same or approved Hearthstone replacement parts These components affect the combustion qualit...

Page 9: ...0 et 2000 pieds 0 610 m seulement Items Required for Installation External regulator for propane LP only LP conversion kit for propane only Piping which complies with local codes Pipe sealant approve...

Page 10: ...ont panel by lifting up and off of the stove body Set aside on a soft surface Figure 3 Front Panel Removal 3 Remove glass by rotating retention clips up until clear of the clip slot Lean the glass awa...

Page 11: ...S WHICH THROUGH TESTING IN AN INDEPENDENT LABORATORY TO ANSI AND CSA STANDARDS WILL PREVENT FIRE OR SPONTANEOUS COMBUSTION WE DO NOT CONTROL THE COMBUSTIBLE MATERIALS EXPOSED TO HEAT BY THIS PRODUCT T...

Page 12: ...odel 8302 is approved for installation only with the vent connecting components listed in this manual Use the following instructions along with the pipe manufacturer s instructions to complete the ins...

Page 13: ...lumbing in the chosen wall location Move the stove and pipe assembly back until the 90 elbow is flush to the wall Ensure the 2 vertical pipe is still parallel to the wall Draw a circle around the pipe...

Page 14: ...ON VENTING CONFIGURATIONS A minimum of 24 rise is required with or w o offsets 40 maximum system height without offsets Maximum rise to run 1 to 5 The termination must meet the requirements outlined i...

Page 15: ...Hearthstone Quality Home Heating Products Inc CHAMPLAIN Model 8302 14 Figure 12 Approved DV Venting Alternate Configurations for Vertical Termination...

Page 16: ...lity Home Heating Products Inc CHAMPLAIN Model 8302 15 Figure 13 Venting Configuration and Restrictor Settings To adjust your restrictor for optimum flame appearance follow the instructions in Restric...

Page 17: ...m CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center...

Page 18: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Page 19: ...R GLEMENTS SELON LES CODES D INSTALLATION CAN CGA B149 NFPA Code and Hearthstone require the use of a dedicated sediment trap just upstream of the unit Damage to the valve or other components due to...

Page 20: ...rosive leak detection fluid or other approved leak detection method around the diaphragm flanges pipe connections seal cap and all other joints Bubbles indicate a leak 2 If no leakage is detected proc...

Page 21: ...ows for better line of sight see notice below 3 When the RF receiver is placed in the appliance the surrounding metal can reduce reception considerably The position of the antenna on the receiver also...

Page 22: ...leak is detected tighten pipe connections including adapters according to GAS CONNECTIONS page 18 Manual Ignition Optional 1 Remove orange ignition wire from Control module and insert onto Piezo Igni...

Page 23: ...y go out if the pilot flame is too small or misdirected away from the thermopile WARNING THE CONTROL HAS AN INTERLOCK DEVICE IF THE STOVE HAS BEEN LIT IT WILL NOT RELIGHT AGAIN IMMEDIATELY AFTER SHUTT...

Page 24: ...ockwise until it bottoms out The low pressure orifice must also be changed see figure 22 27 pages 24 25 NOTE Do NOT adjust and or alter any components marked with tamper indicating paint To Switch the...

Page 25: ...in the valve snug it down until it stops turning by turning clockwise 9 Swing the valve mounting bracket back up into its original position 10 Tighten the two front mounting screws and assure valve b...

Page 26: ...Gate protruding toward the front of the pilot tower and the letters NAT should be visible on the upper horizontal surface see figure 28 Slide the gate backward in the Pilot Tower by pushing on the up...

Page 27: ...N OFF switch on the valve to OFF 4 Replace valve access panel 5 Turn the gas supply valve to the off position FINAL CHECK Observe several complete cycles to ensure proper operation During these cycles...

Page 28: ...s in this section 1 If not already opened follow the instructions for firebox access on page 9 2 Remove the packaging material around the log set assembly Be careful not to damage the log set when unp...

Page 29: ...cast iron panels are re installed follow start up procedure outlined below Air Shutter The air shutter is used to regulate the air to gas combustion mixture which in turn influences the size and color...

Page 30: ...tions cannot be corrected through air shutter adjustment an adjustment must be made to the gas supply pressure Supply line manifold gas line pressure adjustments must be performed by qualified service...

Page 31: ...estrictor Fully Open Detail baffle removed for clarity Figure 36 Restrictor Adjuster Arm Detail Maxitrol GV60 Control System Features NOTE REMOVE THE MODESTY PANEL BELOW THE FRONT CASTING FOR ACCESS T...

Page 32: ...commended Low battery indicator on handsets with display Battery replacement is recommended after 2 years Batteries Receiver 4 x 1 5V AA quality alkaline recommended Low battery indication frequent be...

Page 33: ...will ignite after the Main Valve knob is turned past the minimum setting Once the main burner is on continue turning the Main Valve knob until the desired flame height is reached 10 If the Main Burne...

Page 34: ...tton C to decrease flame height or to set appliance at pilot flame For fine adjustment tap button A or C Designated Low Fire and High Fire Double click small flame button LO will be displayed NOTE Fla...

Page 35: ...but no flame press and hold the small flame button and turn to Pilot flame NOTE The light bulb icon is displayed during light dimmer setting only 8 seconds after the light dimmer has been set the han...

Page 36: ...F and adjusts fan speed NOTE To turn OFF fan press small flame until all 4 speed bars disappear Nighttime Setback Temperature Mode Appliance must be in standby mode pilot ignited The room temperature...

Page 37: ...press SET button to scroll to TEMP mode sun icon Hold the SET button until the set temperature on the screen flashes Press large flame button to increase Daytime Set Temperature Press small flame but...

Page 38: ...sun icon displayed and the time flashes Set the hour by pressing the large flame button Set the minutes by pressing the small flame button Setting P1 OFF Time Select Timer Mode by briefly pressing th...

Page 39: ...Day Shut Off CSA version The system shuts off the fire completely if there is no change in flame height for 5 days NOTE Before the next ignition there is a 2 minute waiting period Routine Maintenance...

Page 40: ...qualified service personnel as described on page 22 Complete the cleaning procedure by carefully placing the log set within the firebox as described on pages 26 28 Reattach the glass and front panel t...

Page 41: ...ass from the glass frame by drilling out the four 1 8 rivets that lock the glass in place Pull the glass away from the frame and set it aside If replacing gasket only 1 Remove the existing gasket from...

Page 42: ...XCHANGER BASE 5301 080 OUTLET RESTRICTOR CLIP 2310 860 HEAT EXCHANGER 5701 925H STARTER COLLAR 2310 240 EXHAUST BAFFLE 7000 027 THERMOCOUPLE INTERRUPTER 3030 036 GLASS 7000 360 REMOTE CONTROL 3160 080...

Page 43: ...will not stay lit after carefully following lighting instructions A Low or too high gas pressure B Faulty connections C Pilot dirty or plugged D Thermocouple damaged E Thermocouple Interrupter circuit...

Page 44: ...locked the rate at which the exhaust leaves draft determines the rate at which the combustion air is delivered Poor draft results in insufficient air delivery or a restricted exhaust Correct air intak...

Page 45: ...44 07044 2 RATING LABEL...

Page 46: ...d will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or one year whichever is longer Parts Hearthstone will replac...

Page 47: ...rials ash grates and glass 4 Damage resulting from installation modification alteration repair or service of the appliance by any party other than an authorized Hearthstone dealer a Dealer or their de...

Page 48: ...ealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site www hearthstonestoves com if the original dealer is not available to find...

Reviews: