– Front Panel Removal 

3.  Remove glass by rotating retention clips up until 
 

clear of the clip slot.  Lean the glass away from the 
firebox at the top and pick straight up off of the 
stove. 

 

 

 

 

 

Figure 4 

– Glass Removal 

 

4.   Reinstall by reversing the previous steps. 

 

Clearances to Combustibles 

 

Note:  Ensure  clearances  are  in  accordance  with 
local  installation  codes  and  the  requirements  of 
the  gas  supplier.  Dégagement  conforme  aux 

codes  d’installation  locaux  et  aux  exigences  du 
foumisseunde gaz.

 

 

Due to high surface temperatures, locate the unit 
out  of  traffic  areas  and  away  from  furniture  and 
draperies.  Do  not  place  clothing  and  other 
flammable  material  on  or  near  the  heater.  When 
positioning  the  unit  always  maintain  adequate 
clearances  around  air  openings  into  the 
combustion  chamber  and  allow  for  adequate 
ventilation.  Minimum  clearances  to  combustibles 
must be maintained as shown in Figures 5 - 8.

 

Note:

  The  rear  clearance  to  combustibles  is 

determined  by  either  the  unit’s  or  the  vent  pipe’s 
minimum  clearance,  depending  on  whether  the 
installation  calls  for  vertical  rise  within  the  room  or  a 
rear  exit,  through-the-wall  vent  pipe.    Ensure  you 
consider the need for access to the gas control valve 
access  door  on  the  front  of  the  unit  as  well  as  full 
access  for  periodic  cleaning  and  servicing.  Also 
consider  clearance  for  the  blower  assembly  if 
present, or planned in the future 

 

CAUTION:  THESE  CLEARANCES  REPRESENT 
MINIMUM  
DISTANCES  IN  ALL  CASES,  WHICH, 
THROUGH 

TESTING 

IN 

AN 

INDEPENDENT 

LABORATORY  TO  ANSI  AND  CSA  STANDARDS, 
WILL 

PREVENT 

FIRE 

OR 

SPONTANEOUS 

COMBUSTION.  WE  DO  NOT  CONTROL  THE 
COMBUSTIBLE  MATERIALS  EXPOSED  TO  HEAT 
BY 

THIS 

PRODUCT; 

THEREFORE, 

AN 

ASSESSMENT 

MUST 

BE 

MADE 

BY 

THE 

INSTALLER 

TO 

PREVENT 

CONSEQUENTIAL 

DAMAGE OF WALLS AND FLOORING. 

Hearth Requirement/Floor 
Protection 

You  can  place  the  Champlain  directly  on  any  non-
combustible  surface  or  on  a  wood  floor.    When 
placing  the  Stowe  on  any  other  type  of  combustible 
surface you must install a panel made of metal, wood, 
stone,  or  glass  under  the  appliance.  The  panel  must 
extending  the  full  width  and  depth  of  the  appliance. 
Installations must meet all local codes. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 5 - Minimum Wall Clearances Horizontal Vent 

 

Summary of Contents for Champlain 8303

Page 1: ...service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licen...

Page 2: ...Page 1 of 35 Intentionally Blank...

Page 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 4: ...irement Floor Protection 9 Venting Information 10 Venting Connection 10 Approved Systems 11 Minimum Venting 12 Electrical System Information 16 Gas Supply Connections 17 Gas Connections 17 Initial Lea...

Page 5: ...Room 1511 Boston Massachusetts 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Cham...

Page 6: ...will remain appealing while providing years of quality performance The installation must conform to local codes or in the absences of local codes the current National Fuel Gas Code ANSI Z223 1 NFPA 5...

Page 7: ...E COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI ACCOMPAGNENT L APPAREIL Hot Surfaces Certain exposed surfaces of the Champlain will reach high tempe...

Page 8: ...their absence the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 or CAN CGA B149 Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon le...

Page 9: ...ALL OR PUT INTO SERVICE A DAMAGED OR INCOMPLETE HEATER Remove the shrink wrap and other packaging materials taking care not to damage the stove s finish Inspect the Champlain for visible or concealed...

Page 10: ...either the unit s or the vent pipe s minimum clearance depending on whether the installation calls for vertical rise within the room or a rear exit through the wall vent pipe Ensure you consider the...

Page 11: ...ENSURE NO WIRING OR PLUMBING IS IN THE CHOSEN LOCATION CAUTION DO NOT RECESS VENTING TERMINATIONS INTO A WALL OR SIDING Note If you need further direction for installation please refer to the venting...

Page 12: ...it Chimney Liner Flex Co Linear Flex Connector Axial to Co Linear Appliance Connect Masonry approved not to exceed 16 measured from stove top IF THE VENT SYSTEM IS DISASSEMBLED FOR ANY REASON IT MUST...

Page 13: ...cover will fit properly Screw the thimble cover to the wall The adjustment range for wall thickness for this configuration is 3 min to 9 max II FIREPLACE VENTING INSTALLATIONS 40 maximum system height...

Page 14: ...Hearthstone Quality Home Heating Products Inc CHAMPLAIN Model 8303 13 Figure 12 Approved DV Venting Alternate Configurations for Vertical Termination...

Page 15: ...lity Home Heating Products Inc CHAMPLAIN Model 8303 14 Figure 13 Venting Configuration and Restrictor Settings To adjust your restrictor for optimum flame appearance follow the instructions in Restric...

Page 16: ...m CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center...

Page 17: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Page 18: ...ng system at test pressures equal to or greater than psig Over pressurizing can damage the control resulting in leakage or control malfunction NOTICE A QUALIFIED TECHNICIAN MUST CONNECT THE HEATER TO...

Page 19: ...in a fire or explosion GAS CONNECTIONS Connection Main Gas Tubing connections 1 Do NOT use pipe joint compound or Teflon PTFE tape 2 Slip nut and ferrule over tubing 3 Slide nut and ferrule into place...

Page 20: ...rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combustion Incorrect log placement may cause carbon build up excess t...

Page 21: ...o use all of the Charcoal Embers Keep the rest for use in the future Do not drop the embers into the burner holes Locate and open the bag of Platinum Bright Embers Pull apart small pieces of the wool...

Page 22: ...st engulf the thermopile so that the thermopile can generate sufficient milli voltage 325 to 500 mv to power the millivolt gas control valve Before lighting smell or use a gas detector all around the...

Page 23: ...r can select the optimum flame size for their setting and application Also available is a optional variable speed blower Air Shutter The air shutter is used to regulate the air to gas combustion mixtu...

Page 24: ...minutes enabling the entire unit to reach temperature and for the flame pattern to stabilize The flame pattern should be similar to the one shown in figure 21 There are several guidelines to aid in de...

Page 25: ...tial for discoloration of the castings or enamel when the residue of the cleaners or polishes is exposed to heat Excessive buildup of dust spider webs or room air contamination may cause odors when th...

Page 26: ...e inspection par un technicien professionnel avant d tre utilis et au moins une fois l an par la suite Des nettoyages plus fr quents peuvent tre n cessaires si les tapis la literie et cetera produisen...

Page 27: ...R CAUTION DO NOT CLEAN THE GLASS WHILE THE UNIT IS HOT Venting Components Venting should not need to be disassembled for normal cleaning However if venting is required to be removed for any reason thi...

Page 28: ...EXCHANGER BASE 7000 350 ORIFICE BURNER NG 31 SPUD 2310 860 HEAT EXCHANGER 7210 103 IGNITOR 23X0 040 TOP CASTING 7211 332 PILOT ASSEMBLY 23X0 440 FRONT CASTING 7211 320 VALVE NG 3030 036 GLASS 7211 01...

Page 29: ...fter sitting for off season summer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pre...

Page 30: ...embly If the meter reading is OK but the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning de...

Page 31: ...Clear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the bur...

Page 32: ...Hearthstone Quality Home Heating Products Inc CHAMPLAIN Model 8303 31 07044 2 RATING LABEL...

Page 33: ...during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or one year whichever is lon...

Page 34: ...nt gaskets baffles refractory materials ash grates and glass 4 Damage resulting from installation modification alteration repair or service of the appliance by any party other than an authorized Heart...

Page 35: ...ance for repair or to schedule a Dealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site www hearthstonestoves com if the origin...

Reviews: