HearthStone Quality Home Heating Products Inc
Champlain
Model #8300
7
SPECIFICATIONS:
L
ISTED
:
D
IRECT
V
ENT
G
AS
H
EATER
Listed:
DV Gas Heater
Model:
Champlain DV Room Heater
Testing Agency:
Intertek Testing Services NA Inc. (ITS)
Tested to:
ANSI Z21.88-1998, CSA 2.33-M98, CAN/CGA2.17
Figure 1: Champlain Dimensions
NG
LP
Input rating (Btu/hr) 0-2000ft
37,000 37,000
Maximum output (Btu/hr) 0-2000ft
26,200 26,800
Minimum input rating (Btu/hr)
20,300 22,600
Orifice size DMS 0-2000ft
31
49
Man. pressure- HI setting (in.w.c./kPa)
3.5/0.84 10.0/2.48
Man. pressure- LO setting (in.w.c./kPa)
1.2/0.30 3.3/0.80
Inlet pressure-HI (in.w.c./kPa.)
7.0/1.74 13.0/3.22
Inlet pressure-Lo (in.w.c./kPa)
5.0/1.24 11.0/2.75