Follow these special requirements for installing your
stove in a mobile home.
•
Install the stove in accordance with 24 CFR,
Part 3280 (HUD)
•
An outside air kit must be used in all mobile
home installations. See page 12 for details.
•
Permanently attach the stove to your mobile
home’s floor. Use the shipping clips that came
with the stove and fasteners long enough to
attach securely to the subfloor. (The clips and
fastener heads may be painted to minimize
visibility).
Figure 11 - Lock Down Detail
•
Install a Mobile Home Chimney & Connector
Kit*.
Each kit must include:
Stainless spark arrester cap, storm collar,
Adjustable vented flashing
– 0/12 – 6/12,
Two 24” chimney pipes, 24” support box
with built-in starter section and trim.
* Install a Mobile Home Chimney and Connector Kit
conforming to US/UL103 or CAN/ULC-S629, Standard for
Factory-Built Chimneys.
•
WARNING: DO NOT INSTALL IN A SLEEPING
ROOM IN A MOBILE HOME.
•
CAUTION: MAINTAIN THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME WALLS,
FLOOR, CEILING, AND ROOF WHEN
INSTALLING AND USING YOUR STOVE.
•
FAILURE TO FOLLOW THESE
INSTRUCTIONS AND SPECIFIED
COMPONENTS OR USING MAKE-SHIFT
COMPROMISES CAN RESULT IN FIRE,
PROPERTY DAMAGE, BODILY INJURY, AND
EVEN DEATH.
•
Burning any fuel other than wood in this unit
could generate dangerous levels of carbon
monoxide within the living space.
•
THE FRONT DOOR MUST REMAIN CLOSED
WHEN IN OPERATION EXCEPT FOR START
UP AND LOADING. Leaving the door open
during use could cause any smoke or fire
detectors in the home to be set off or a fire could
escape the firebox and start the room on fire.
•
If this unit is installed in a mobile home, care must
be taken to ensure adequate air is available. If
not enough air is available it could starve the
room of all the oxygen. (See page 27 for more
details)
•
The chimney should be attached directly to the
stove and must extend at least 3 feet (.9 m) above
the part of the roof through which it passes. The
top of the chimney is to be at least 2 feet (.6 m)
above the highest elevation of any part of the
mobile home within 10 feet (3 m) of the chimney.
•
All roof-chimney terminations should be able to
be readily removed / re-installed at or below an
elevation of 13-1/2 feet (4.1 m) above ground
level without the use of special tools or
instructions. The chimney assembly shall be
provided with a mechanical securement means to
secure the chimney to the ceiling support box.
•
When a chimney exits the mobile home at a
location other than through the roof, and exits at
a point 7 feet (2.1 m) or less above the ground
level on which the mobile home is positioned, a
guard or method of enclosing the chimney shall
be provided at the point of exit for a height up to
7 feet.
•
The chimney guard shall not allow the passage of
a ¾ inch (19.1 mm) diameter rod, and a ½”
(12.7 mm) diameter rod shall not be able to touch
the chimney when inserted through any part of
the guard a distance of 4 inches (102 mm).