The gas fireplace is shipped with a 3/8” tube OD (male) connection. The gas supply piping should have a
separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The stove and its main
control valve must be disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psi (3.5 kPa). The stove must be isolated from the gas supply piping
system by closing the main control valve during any pressure testing of the gas supply system at test pressures
equal to or greater than 1/2 psi (3.5 kPa). After the gas supply has been connected, use a commercial gas leak
detector or apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for
leaks.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts. If this appliance is installed in a dwelling, building or structure
used in whole or in part for residential purposes and the installation includes a horizontal vent
termination that is less than seven (7) feet above the finished grade in the area of the venting,
including but not limited to decks and porches, a hard-wired carbon monoxide detector with an alarm
and battery back-up must be installed on the floor level of the dwelling, building or structure where
the appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be
installed on each additional level of the dwelling, building or structure served by the appliance. It
shall be the responsibility of the property owner to secure the services of qualified licensed
professionals for the installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is installed in a crawl space or attic, the hardwired
carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor
level.
In the event that this requirement cannot be met at the time of completion of the installation of the
appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However,
during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be
installed.
Each carbon monoxide detector as required in accordance with the above provisions must comply
with NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition when the vent termination is less than seven (7) feet above finished grade a metal or
plastic identification plate must be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign shall read,
in print size no less than one-half (1/2) inch in
size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF
ALL OBSTRUCTIONS”.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH INCLUDE PARTS
LISTS, AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT THE
COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting system was used in the installation. These
instructions must remain with the Orion Installation & Operation Manual.