Hearthstone Quality Home Heating Products, Inc.
BARI Model #8180
S
AFETY
R
ATING
L
ABEL
SERIAL #
MODEL #
8180-
M ODE L NA ME: BARI GAS DIRECT VENT GAS FIRED HEATE R
LISTED: GAS FIRED DIRECT VEN T HEATER
TESTED TO: ANSI Z21.88b-2005/CSA 2.33b-2005
CGA-2.17-M91
CER TIFIED FOR A ND US CANA DA
HOM OLOGUE PO UR LE CANAD A
ALSO FOR MOBIL E HOM E INSTALLAT ION
INPU T RA TING (Btu/hr) 0-200 0 ft
INPU T RA TING (Btu/hr) 2000- 4000 FT
ORIF ICE S IZE (DMS ) 0-2 000 ft
MAN IFOLD PRESSU RE - LO (in. w. c./kp a)
MAN IFOLD PRESSU RE - HI ( in. W.c./kpa)
MINI MUM INLE T PR ESS URE (in. W.c./k pa)
MINI MUM INPU T (btu/hr ) 0/2000 ft
MAX IMUM OUTPUT (btu/hr) 0-200 0 ft
26,500
26,500
38
1.2/0.3
3.5/0.87
5.0/1.24
16,000
19,600
2 6,500
2 6,000
52
3.3/0. 8
10.0/2. 48
11.0/2. 88
1 5,000
2 0,100
NG
LP
MINIMUM CLEARANCES TO COMBUSTIBLES
UNIT TO REAR WALL
UNIT TO S IDE WALLS
CORNER
1” / 25 mm
10” / 254 mm
7”/ 178 mm
VEN TED GAS FIRE PLAC E HE ATE R - N OT FO R USE W ITH SOLI D FU EL.
MANUFACT URED BY: HearthStone, MORRISVILLE , VERMON T 05661
Date of Manufacture
2007 2008 2009 J an Feb Ma r Apr M ay Jun Jul A ug S ep Oct Nov Dec
DO NOT RE MOV E OR COVER THIS LABE L
MADE IN USA
3300-586
FUEL T YPE:
Th is app liance is only for us e with the type of gas ind icated on this r ating plate and may be installed in an aftermarket,
perman ently locat ed, manufactur ed (m obile) home w here not p rohibited by lo cal codes. See owne r’s m anual for detai ls. This
ap plianc e is not conve rtible for use with other gases, unle ss a certified ki t is us ed. I f the vent air int ake s ystem is
dis asse mbled for any r easo n, reinstal l per the instructions prov ided with the in itial instructions . This ven ted gas fireplace
he ater is not for us e wi th air filters . This app liance must be prop erly connected to a venti ng sy stem in accordance with the
manufacturer’s ins talla tion instructions .
CAU TION: DO NOT OPERATE WIT H GLASS REMOVED , CRACKE D, OR BR OKEN.
Rep lacement on the panel should be done b y a licensed or quali fied service person.
CAU TIONNER: N’op r e l’appareil avec le ver ra enl ve, craque ou casse. L e
rem placemen t du panne au devrait tre fait p ar une per sonne de service qu alifi ou autoris .
è
ê
è
é
é
This app liance must be installed in acc ordance w ith the loc al cod es, i f
any, if no t; follow t he Nationa l Fuel Gas Code, AN SI Z223.1 or
Canadian Installat ion Codes, CSA B14 9.1.
WARNIN G: Impro per installa tion, adjus tment, alt eration, service or
mainten ance can cause inju ry or prope rty damag e. Refer to the
owner's informatio n manual p rovided w ith this ap pliance. F or
assistan ce or additional infor mation co nsult a qua lified insta ller, servic e
agency or the gas supplier.
(Installer l'appareil selon les
codes ou ré
glement s locaux, ou, en l'abs ence de te ls régleme nts, selon les Codes
d'installation CSA- B149.1)
( L'AVERTIS SEMENT: L'installation
inconven ante, ajus tement, modification , service o u entretien peut
causer l e dommag es de pro priété ou b lessure. Référer au manuel
d'informa tion de pr opriétaire fourni cet appareil. Po ur l'assista nce ou
informat ion supplé mentaire c onsulte un qualifiée i nstalleur, agence de
service o u le fourn isseur de g az .)
REPORT N o. 3109401-T1
31