Hearthstone Quality Home Heating Products, Inc.
Bari Model #8180
S
PECIFICATIONS
Certified for use by:
Board of State Examiners of Plumbers and
Gasfitters
100 Cambridge Street, Room 1511
Boston, Massachusetts 02202
L
ISTED AS
:
Gas-Fired Direct-Vent Fireplace Heater
Model:
Bari Direct-Vent Gas Fireplace Heater
(#8180)
Testing Agency:
Intertek Testing Services
Tested to:
ANSI Z21.88b-2005/CSA 2.33b-2005,
CGA 2.17-M91
Report No.
3109401-T1
Certified for US and Canada. Approved for Mobile
Home Installation
Figure 1: Bari DV Model 8180 Dimensions
Specification NG
LP
INPUT RATING (Btu/hr) 0-2000 ft
26,500
26,500
INPUT RATING (Btu/hr) 2000-4000 ft
26,500
26,000
ORIFICE SIZE (DMS) 0-2000 ft
38
52
ORIFICE SIZE (DMS) 2000-4500ft)
38
53
MANIFOLD PRESSURE - LO SETTING (in. W.c./kpa)
1.2/0.3 3.3/0.8
MANIFOLD PRESSURE - HI SETTING (in. W.c./kpa)
3.5/0.87 10.0/2.48
MINIMUM INLET PRESSURE - (in.w.c./kpa) 5.0/1.24
11.0/2.88
MAXIMUM INLET PRESSURE- (in.w.c./kpa)
7.0/1.74
13.0/3.22
MINIMUM INPUT RATING (btu/hr)
16,000
15,000
MAXIMUM OUTPUT (btu/hr) 0-2000 ft
19,600
20,100
6