background image

Hearthstone Quality Home Heating Products, Inc.                                                                    

   

         Bari Model #8180 

I

NSTALLER

I

NFORMATION

 

C

ODES

 

Adhere to all 

local codes

 or, in their absence, the 

latest edition of THE NATIONAL FUEL GAS CODE 
ANSI Z223.1 (NFPA 54) or CAN/CGA B149. 
Installation Code that can be obtained from:

 

AMERICAN NATIONAL STANDARDS INSTITUTE, INC.

 

1430 BROADWAY 
NEW YORK, NY 10018 
www.ansi.org 

OR 

NATIONAL FIRE PROTECTION ASSOCIATION, INC.

 

BATTERY MARCH PARK 
QUINCY, MA 02269 
www.nfpa.org 

A manufactured home (mobile) OEM installation 
must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, 
Part 3280 (U.S.) or Standard for Manufactured 
Home Installation, ANSI/NCBCS A225.1 or Standard 
for Gas Equipped Recreational Vehicles and mobile 
Housing, CSA Z240.4.CAN/SCA Z240 MH 
(Canada).    

(Installer l’appareil selon les codes ou 

règlements locaux, ou, en l’absence de tels 
règlements, selon les Codes d’installation 
CAN/CGA-B149.)  

I

TEMS 

R

EQUIRED FOR 

I

NSTALLATION

 

External regulator (for  LP) 

Phillips head screwdriver 

Code Compliant Piping  

7/16-inch wrench 

Pipe sealant approved for 
use with LP 

Other parts as required by 
local code 

Manual shutoff valve 

*Safety Glasses 

Sediment trap (page 17) 

*Gloves 

Tee joint 

 

Pipe wrench 

 

*Recommended

 

P

ACKING 

L

IST

 

1-Bari Gas-Fired Heater 

2-Accessory boxes 

1-Decorative Fire logs Set 

1-Venting/stove connector 

1-Set Bari Stone Panels 

1-Remote control receiver 

1-Owner’s Manual 
1-Warranty Validation 
Form 

1- Bag of Platinum Bright 
Embers 

Note:

 Vent kits and components are supplied separately.  

Failure to use the venting components specified by 
Hearthstone will void your warranty and could risk a fire. 

S

PECIFIED 

V

ENTING 

M

ANUFACTURERS

 

The heater is approved for installation only with the 
venting components provided by manufactures listed 
on

 

this page.

 

 

Simpson Dura-Vent, Inc. 
P.O. Box 1510 
Vacaville, CA 95696-1510   

800-835-4429 

 

American Metal Products 

(AmeriVent)

 

8601 Hacks Cross Rd. 
Olive Branch, MS 38654   

800-423-4270 

 

Selkirk Corporation 
1301 W. President George Bush Hwy, Suite 330 
Richardson, TX 75080-1139 

800-992-8368 

 

Security Chimneys International Ltd 

(Secure Vent) 

2125 Monterey, Laval, Quebec 
Canada, H7L 3T6  

 

450-973-9999 

 

ICC, Inc. 
400 J-F Kennedy, St. Jerome, Quebec 
Canada, J7Y 4B7  

 

450-565-6336 

 

Metal-Fab, Inc. 
P.O. Box 1138 
Wichita, Kansas 67201 

 

316-943-2351 

U

NPACKING AND 

I

NSPECTION 

 

Unpack and Inspect for Damage - 

The Bari is packaged to withstand normal shipment 
without damage. However, damage can still occur 
during transit; so take care to inspect for damage 
when unpacking and installing the unit. If any 
damage or missing parts are detected, immediately 
contact your dealer

.    

 

Do not install, or put into service, a damaged 
or incomplete heater.

   

 

The Bari requires a pilot shield. This shield is 
shipped with the unit. Ensure the shield is 
installed over the pilot with the open end to 
the left (when you are facing the front of the 
unit). 

Inspect the Bari for visible or concealed damage. 
The unit should appear to be square and true, with 
sheet metal parts smooth and free of bends and 
dents. The painted surfaces should be free of 
scratches flaking, or blemishes. If visible or 
concealed damage is found or suspected, contact 
your dealer for instructions. 

Always use great care when handling the decorative 
fire logs, as they are fragile and subject to damage 
and breakage if handled roughly. If a broken log is 
encountered, contact your dealer for replacement 
logs. Otherwise, set the logs aside until called for 
during the installation.

 

 

 

 

8

Summary of Contents for hase-Bari 8180

Page 1: ...staller service agency or gas supplier must perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by...

Page 2: ...Hearthstone Quality Home Heating Products Inc Bari Model 8180 Intentionally Blank 2...

Page 3: ...eep your original receipt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installatio...

Page 4: ...ION 12 VENT CONNECTION 12 RESTRICTOR PLATE 12 VENTING COMPONENTS CONFIGURATION 14 ELECTRICAL CONNECTIONS 16 GAS SUPPLY CONNECTIONS 17 FIRE LOG PLACEMENT 18 OPERATION 20 LIGHTING THE UNIT FOR THE FIRST...

Page 5: ...STRIKING OR SLAMMING SHUT REPLACEMENT OF THE GLASS PANEL SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON NEVER BURN PAPER WOOD OR OTHER MATERIALS This gas heater is designed to burn natural g...

Page 6: ...No 3109401 T1 Certified for US and Canada Approved for Mobile Home Installation Figure 1 Bari DV Model 8180 Dimensions Specification NG LP INPUT RATING Btu hr 0 2000 ft 26 500 26 500 INPUT RATING Btu...

Page 7: ...he unit or venting system chimney immediately discontinue operation of the unit and contact qualified service personnel Clean the area around under and behind the unit on a regular basis to prevent th...

Page 8: ...D VENTING MANUFACTURERS The heater is approved for installation only with the venting components provided by manufactures listed on this page Simpson Dura Vent Inc P O Box 1510 Vacaville CA 95696 1510...

Page 9: ...EPENDENT LABORATORY TO ANSI AND CSA STANDARDS WILL PREVENT FIRE OR SPONTANEOUS COMBUSTION WE DO NOT CONTROL THE COMBUSTIBLE MATERIALS EXPOSED TO HEAT BY THIS PRODUCT THEREFORE AN ASSESSMENT MUST BE MA...

Page 10: ...Hearthstone Quality Home Heating Products Inc Bari Model 8180 2 minimum vent pipe clearance to combustibles Figure 4 Minimum Vent Configuration and Clearances 10...

Page 11: ...y recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center line of the reg...

Page 12: ...ent configurations Controlling the draft also changes the aesthetics of the flame The restrictor plate consists of a rotating shutter in the flue connector This shutter is attached to a rod that protr...

Page 13: ...Hearthstone Quality Home Heating Products Inc Bari Model 8180 NOTE These positions are based on lab results and can have some variance Figure 8 Venting Configurations Restriction Settings 13...

Page 14: ...tallations 90 0 Elbow Vertical Vent Cap 45 0 Elbow 36 Snorkel 6 Straight 9 Straight Simpson only Vinyl Siding Standoff 4 x 6 5 8 12 Straight Round Ceiling Support 24 Straight Thimble Covers 36 Straigh...

Page 15: ...ent termination to the outside of the house run a bead of non hardening mastic around its outside edges to ensure a good seal between it and the wall Ensure the arrow on the end cap points up Secure t...

Page 16: ...living space as the unit Since the transmitter is the device measuring the temperature you will want to keep it off the floor and away from any influences that may cause the temperature in the vicini...

Page 17: ...of pressure We recommend a flexible line to avoid undue mechanical load on the valve and to ease thread alignment but refer to local codes CAUTION CHECK FUEL GAS TYPE GAS SUPPLY Isolate the Bari from...

Page 18: ...if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combustion Incorrect log placement may cause carbon bu...

Page 19: ...the seam 7 Sprinkle the charcoal embers over the burner ports only Ensure that you leave the ports open over the pilot and where the main burner ignites WARNING DO NOT PLACE ANY CHARCOAL EMBERS OR RO...

Page 20: ...mpts the pilot light fails to light using the piezoelectric ignitor discontinue operation turn off the gas to the gas control valve and immediately contact qualified service personnel for assistance P...

Page 21: ...he remote to ON Then set the desired temperature 9 Shut the gas control valve access door 10 If Remote was selected set remote to ON and set desired temperature setting Normally if Remote position was...

Page 22: ...the locking nut without turning the screw The air shutter is factory set and only a qualified gas technician should make adjustments Note Very little movement is needed to substantially change the bu...

Page 23: ...o reach temperature and for the flame pattern to stabilize The flame pattern should be similar to the one shown in Figure 14 There are several guidelines to aid in determining if the flame pattern is...

Page 24: ...e large enough to engulf the thermopile and thermocouple as shown in Figure 13 NOTE Do not operate the unit for more than 1 2 minutes without the log set in place Turn the unit off by setting the ther...

Page 25: ...BUSE SUCH AS STRIKING OR SLAMMING SHUT REPLACEMENT OF THE GLASS PANEL SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON VENTING The venting system should receive a periodic examination by a qua...

Page 26: ...e screws not provided screw the steel plate to the framing in the wall Once the screws are in place and the stove is in its proper location tighten the two screws that hold the two plates together HIG...

Page 27: ...404 KNOB EXTENSION HIGH LOW 7211 370 PILOT ASSEMBLY NG 3 port 7200 338 NG ORIFICE MAIN ORIFICE 38 SPUD 91 56800 LP CONVERSION KIT 91 56803 HIGH ALTITUDE CONVERSION KIT LP Only 1141 820 149 V RIGHT ST...

Page 28: ...on If properly connected and no spark replace igniter E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure B F...

Page 29: ...replace Note do not use any metal cleaning device as this may damage the orifice 4 Pilot and burner come on but go out after some warm up A Inconsistent or insufficient flame on thermopile B Insuffic...

Page 30: ...ns B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orif...

Page 31: ...sed If the vent air int ake system is disasse mbled for any r easo n reinstal l per theinstructions prov ided with the in itial instructions This ven ted gasfireplace he ater is not for use wi th air...

Page 32: ...Hearthstone Quality Home Heating Products Inc BARI Model 8180 32 NOTES...

Reviews: