Hearthstone Quality Home Heating Products, Inc.
Heritage Model 8090 Pellet Stove
Page 25 of 53
Venting
I
NSTALLATION
E
XAMPLE
:
C
OAXIAL
D
IRECT
V
ENTING
Use of this method is acceptable as long as there is no combustible material within 36” of the termination,
and the termination is at least 18” above grade.
There may be smoke spillage into the room if there is a power outage. The outside air vent must be
connected to reduce this chance.
NOTE:
As your heritage pellet stove is power vented, you can install it (with consideration to exterior
clearances) with this horizontal only exit configuration. However, we recommend a vertical rise of 5 feet
minimum in case of a power outage when some smoke may back up into your heated space. Without any
natural draft, the stove will smoke in this situation. However, the smoke will stop within 10 minutes.