Hearthstone
Quality Home Heating Products, Inc
® Manchester Model 8360
8
H
EARTH
R
EQUIREMENTS
&
F
LOOR
P
ROTECTION
Ensure you protect combustible flooring with a covering of noncombustible material. The Manchester does not
require an insulated hearth pad. The minimum floor protection must be met under the stove and extend beyond
the stove as follows:
The minimum floor protection for US installations is 48in x 36-3/4in.
The minimum floor protection for installations in Canada is 56in x 44in.
*
Installations in Canada require 18” (45.72 cm) of floor protection on both side and front.
**
Rear clearance required only if stovepipe runs horizontally back above the top or behind the stove.
Figure 2
– Hearth Dimensions