Hearthstone Quality Home Heating Products, Inc.
SANTA FE Model 8761
9
V
ENTING
I
NFORMATION
There are many configurations of vent
installations for your stove. Please review
the following pages for the venting
installation that works best for you.
Note:
Vent terminals must not be recessed into
walls, or siding
V
ENT
C
ONNECTION
1. The Santa Fe 1 Direct Vent is approved for
installation only with the vent connecting
components listed on
this page and Simpson
Dura-Vent Direct Vent GS, AmeriVent Direct,
EXCELDirect or Secure Vent systems. Use the
following instructions along with the pipe
manufacturer’s instructions to complete the
installation.
2. Attach the inner starter collar and gasket to
the unit with the eight # 8 x ½" Phillips Head
sheet metal screws.
3. Place the outer starter collar and gasket onto
the back of the stove. Secure the outer adapter
with the eight # 8 x ½" Phillips Head sheet
metal screws that are provided. Install the rest of
the vent system according to the manufacturer’s
instructions.
1.
Gasket 4”
2.
Inner starter
3.
Gasket
4.
Outer Starter
Figure 5
Summary of Contents for Santa Fe 8761