background image

HearthStone Quality Home Heating Products Inc

                                          

SANTA FE 1 Gas-Fired Direct Vent heater                           

20 

 

Figure 14 Typical Flame Pattern

 

 
 

G

AS 

C

ONVERSIONS

 

All Santa Fe stoves are set up for use with 
Natural Gas when built. However, these units 
are easily converted for use with LP, and visa 
versa. The instructions provided with the 
included conversion kit must be followed. 

Only 

a Qualified Gas Technician should do the 
conversion. 
 

For checking, and properly adjusting, the 
manifold pressure, refer to the

 Gas Connection 

section on page 16

 of this manual. 

Leak  test   

before, and after, lighting the stove
 

Fill out the label provided on back of the stove. 
The input rate of the heater can be verified by 
checking the manifold pressure. If the manifold 
pressure is correct, then the input rate is also 
correct. Be sure to check the manifold pressure 
and properly adjust the pilot and main burner 
flames. 
  

R

OUTINE 

M

AINTENANCE 

AND 

C

ARE 

 

The Santa Fe requires minimal routine 
maintenance and care.  The unit should always 
be cool and off when cleaned, or serviced. 

Once a year the unit and venting system should 
be inspected by qualified service personnel to 
ensure that they are clean, prevent the 
accumulation of dust, lint and other debris, free 
of obstruction, safe and in good working 
condition.  To clean the firebox, set the switch to 
the “OFF” position, and turn off the gas at the 
gas control valve. 
 

When the unit is cool

, open the front door and 

carefully remove the decorative ceramic log set 
taking care not to damage the logs or chip the 
enameled cast iron. Clean the pan burner, and 
carefully vacuum the entire surface of the log 
set. Take care to thoroughly vacuum the ports 
(slots) on the top of the pan burner.  
 
With the decorative ceramic logs out of the 
firebox, fasten the door shut and briefly light the 
unit according to

 lighting instructions

 described 

on 

Page 4.

 Check to ensure a flame is burning 

from each burner port. The pilot flame should be 
large enough to engulf the thermocouple and 
thermopile

.

 Turn the unit off by setting the 

switch to 

“Off”

, and turning off the gas control 

valve.  

Allow the unit to cool

.

 

Check and clean 

any burner ports that are not burning, or not 
burning properly. Clean the burner ports using a 
soft brush or vacuum cleaner. Adjust the pilot 
flame height if necessary. 
 
Complete the cleaning procedure by carefully 
placing the log set back in the firebox as 
described on 

Page  17.

 Close and refasten the 

front door. Turn on the gas, light the unit, and 
check for proper operation.   

 

 

WARNING! Do not use abrasives 
when cleaning the glass. 

 
 
 
 

 
 

Summary of Contents for Santa Fe 8761

Page 1: ...e agency or gas supplier must perform installation and service In the Commonwealth of Massachusetts all installation of gas lines and gas fitting shall only be done by a licensed gas fitter or license...

Page 2: ...y claims if necessary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Dat...

Page 3: ...ore use and at least annually ALWAYS VENT TO THE OUTSIDE Never vent the gas heater to other rooms or buildings Do not connect this gas appliance to a chimney flue serving a separate solid fuel burning...

Page 4: ...fic and away from furniture draperies clothing and other flammable materials Alert children and adults to the hazards of high surface temperatures and that they must stay away to avoid burns to skin o...

Page 5: ...Shut the gas control valve access door 10 Plug in the blower accessory if so equipped 11 Set thermostat to ON and set the desired temperature setting Normally if the T STAT position was selected the...

Page 6: ...the information sticker must be filled out by the installer and adhered to the appliance at the same time of conversion Cet appareil est equip pour des altitudes compries entre 0 et 2000 pieds 0 610...

Page 7: ...hutoff valve Sediment trap page 16 Tee joint Pipe wrench Phillips head screwdriver Other parts as required by local code Safety Glasses Gloves AIR SUPPLY The Santa Fe Direct vent does not require addi...

Page 8: ...ensions CLEARANCE TO COMBUSTIBLES 4 MIN 2 MIN 1 MIN Figure 3 Rear and side wall clearances The corner clearance for the Santa Fe is 2 to be measured from the edge of the top castings to the adjacent w...

Page 9: ...Input rating Btu hr 0 2000 ft 35 000 35 000 Input rating Btu hr 2000 4500 ft 35 000 33 300 Orifice size DMS 0 2000 ft 32 51 Orifice size DMS 2000 4500 ft 32 52 Man press LO setting in w c kPa 1 2 0 3...

Page 10: ...on this page and Simpson Dura Vent Direct Vent GS AmeriVent Direct EXCELDirect or Secure Vent systems Use the following instructions along with the pipe manufacturer s instructions to complete the ins...

Page 11: ...Hearthstone Quality Home Heating Products Inc SANTA FE Model 8761 10 Approved Possible Vent TERMINATION locations...

Page 12: ...ked Install the 90 elbow in similar fashion NOTE BE SURE THERE IS NO WIRING OR PLUMBING IN THE CHOSEN WALL LOCATION Move the stove and pipe assembly back until the 90 elbow is flush to the wall The 2...

Page 13: ...w and spin the locator found on the rear left side of the stove Refer to figure 7 Figure 7 II FIREPLACE VENTING INSTALLATIONS 40 maximum system height without offsets 14 maximum offset refer to Figure...

Page 14: ...Hearthstone Quality Home Heating Products Inc SANTA FE Model 8761 13 III VERTICAL TERMINATION VENTING CONFIGURATIONS 40 maximum system height without offsets Figure 8...

Page 15: ...he termination must fall within the area outlined by the shaded area shown in Figure 7 Use a vinyl siding Stand off when installing against vinyl siding Horizontal sections require a 1 4 rise every 12...

Page 16: ...This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used available through your loca...

Page 17: ...nifold gas pressure must be tested The gas control valve has built in pressure taps for test gauge connections The supply line pressure must be tested to ensure it meets the minimum pressure for the t...

Page 18: ...ast a long time however they will break easily if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combust...

Page 19: ...careful not to chip the enamel when fastening the door REMOVAL OF LOG SET Caution Log set and charcoal embers will retain heat and can be very hot if previously lit Allow at least 1 hour after pilot...

Page 20: ...ol knob Never use tools WARNING The control has an interlock device If the stove has been lit it will not relight immediately After shutting off all gas flow the pilot burner cannot be relit until the...

Page 21: ...accumulation of dust lint and other debris free of obstruction safe and in good working condition To clean the firebox set the switch to the OFF position and turn off the gas at the gas control valve...

Page 22: ...WIRING INSTRUCTIONS Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Attention A...

Page 23: ...CLIP 2310 850 HEAT EXCHANGER BASE 7200 351 ORIFICE BURNER HOOD LP 51 SPUD 2310 860 HEAT EXCHANGER 7211 390 3 WAY PILOT HOOD W CLIP 2310 240 EXHAUST BAFFLE 7211 009 PILOT GAS TUBE 3030 028 GLASS 17 15...

Page 24: ...23 07044 2 RATING LABEL...

Page 25: ...mmer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure A Check for proper inlet...

Page 26: ...ut the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orific...

Page 27: ...uctions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creat...

Page 28: ...anship Firebox and firebox baffle against breakage cracking or burn through Convective heat exchanger against breakage cracking or burn through Burners air shutters and orifices against breakage crack...

Page 29: ...o comply with Hearthstone s or a Dealer s request to ship the part or the Stove to Hearthstone or a Dealer as the case may be THE WARRANTIES CONTAINED IN THIS DOCUMENT ARE EXCLUSIVE AND ARE GIVEN BY H...

Page 30: ...r after the Purchase Date Hearthstone will pay for warranty labor performed by a Dealer at Hearthstone s published labor rates in effect at the time the labor is performed Thereafter the Original Purc...