background image

Hearthstone Quality Home Heating Products, Inc.                                                              

   SANTA FE Model 8761                                                   

 

S

ERVICE 

C

AUTION

 

 

Any components of the stove removed for 
servicing must be replaced before operating. If 
you believe your Santa Fe is not performing 
properly, immediately discontinue operation 
until the unit is inspected and approved for 
operation by qualified service personnel. Prior to 
servicing the unit, turn the valve control knob 
clockwise to “OFF”. Ensure the unit is cool 
before servicing and cleaning. 
 

 

WARNING! Any safety screen, guard, or 
component removed during servicing 
must be replaced before operation.  

 
Do not use any components other than those 
approved by Hearthstone Quality Home 
Heating Products, Inc., otherwise all 
warranties are void.
 Do not substitute 
components! 
 
F

IRE 

H

AZARD

 

Do not store, or use gasoline, or other flammable 
vapors or liquids near this appliance. The Santa 
Fe should be located out of traffic, and away 
from furniture, draperies, clothing, and other 
flammable materials. 

 
S

HOCK  

H

AZARD 

(

IF EQUIPPED WITH ACCESSORY FAN

)

  

The accessory blower is equipped with a three-
prong (grounding) plug for protection against 
shock hazard and must be plugged directly into a 
properly grounded three-prong receptacle.  Do 
not cut, or remove, the grounding prong from 
the plug. 
 

H

OT 

S

URFACES

 

Certain exposed surfaces of the Santa Fe will 
reach high temperatures during normal 
operation.  Clearances to combustibles must be 
maintained, as specified in the “Clearances To 
Combustibles” section of this manual. 

Due to 

high temperatures, the appliance should be 
located out of traffic and away from 
furniture, draperies, clothing, and other 
flammable materials. Alert children and 
adults to the hazards of high surface 
temperatures and that they must stay away to 
avoid burns to skin or possible clothing 
ignition. Supervise young children carefully 

when in the same room as the appliance. Do 
not place clothing or other flammable 
material on or near the appliance.  

(Surveille 

les enfants.  

Garder les vêtements, les meubles, 

l’essence ou autres liquides à vapeur 
inflammables lin de l’appareil.)

    Clean the area 

around, under, and behind the unit on a regular 
basis to prevent the accumulation of dust and 
lint. 
 

 

WARNING! Do not operate the appliance 
with the front glass removed, cracked, or 
broken. Replacement of glass should be 
done by a licensed, or qualified service 
person. Only open front for routine 
service. Do not slam, or strike the glass.

 

 
 

O

WNER

I

NFORMATION

 

The installation must conform with local codes 
or, in the absences of local codes, the current 
National Fuel Gas Code, ANSI Z223.1 (NFPA 
54), or CAN/CGA B149 Installation Code. 

(Installer l’appareil selon les codes ou 
règlements locaux, ou, en l’absence de tels 
règlements, selon les Codes d’installation 
CAN/CGA-B149.) 

 

 

Do not use this appliance if any part was 
under water. Immediately call a qualified 
service technician to inspect the heater, and 
to replace any part of the control system that 
was submerged. (N

E PAS SE SERVIR DE CET 

APPAREIL S

IL A ÉTÉ PLONGÉ DANS L

EAU

,

 

COMPLÈTEMENT OU EN PARTIE

.

   

A

PPELER UN 

TECHNICIEN QUALIFIÉ POUR INSPECTOR 

L

APPAREIL ET REMPLACER TOUTE PARTIE DU 

SYSTÈME DE CONTRÔLE ET TOUTE COMMANDE 

QUI ONT ÉTÉ PLONGÉS DANS L

LAU

.) 

 
Certified for use by: 

Board of State Examiners of Plumbers and Gasfitters 
100 Cambridge Street, Room 1511 

Boston, Massachusetts 
02202 

Summary of Contents for Santa Fe 8761

Page 1: ...e agency or gas supplier must perform installation and service In the Commonwealth of Massachusetts all installation of gas lines and gas fitting shall only be done by a licensed gas fitter or license...

Page 2: ...y claims if necessary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Phone Dat...

Page 3: ...ore use and at least annually ALWAYS VENT TO THE OUTSIDE Never vent the gas heater to other rooms or buildings Do not connect this gas appliance to a chimney flue serving a separate solid fuel burning...

Page 4: ...fic and away from furniture draperies clothing and other flammable materials Alert children and adults to the hazards of high surface temperatures and that they must stay away to avoid burns to skin o...

Page 5: ...Shut the gas control valve access door 10 Plug in the blower accessory if so equipped 11 Set thermostat to ON and set the desired temperature setting Normally if the T STAT position was selected the...

Page 6: ...the information sticker must be filled out by the installer and adhered to the appliance at the same time of conversion Cet appareil est equip pour des altitudes compries entre 0 et 2000 pieds 0 610...

Page 7: ...hutoff valve Sediment trap page 16 Tee joint Pipe wrench Phillips head screwdriver Other parts as required by local code Safety Glasses Gloves AIR SUPPLY The Santa Fe Direct vent does not require addi...

Page 8: ...ensions CLEARANCE TO COMBUSTIBLES 4 MIN 2 MIN 1 MIN Figure 3 Rear and side wall clearances The corner clearance for the Santa Fe is 2 to be measured from the edge of the top castings to the adjacent w...

Page 9: ...Input rating Btu hr 0 2000 ft 35 000 35 000 Input rating Btu hr 2000 4500 ft 35 000 33 300 Orifice size DMS 0 2000 ft 32 51 Orifice size DMS 2000 4500 ft 32 52 Man press LO setting in w c kPa 1 2 0 3...

Page 10: ...on this page and Simpson Dura Vent Direct Vent GS AmeriVent Direct EXCELDirect or Secure Vent systems Use the following instructions along with the pipe manufacturer s instructions to complete the ins...

Page 11: ...Hearthstone Quality Home Heating Products Inc SANTA FE Model 8761 10 Approved Possible Vent TERMINATION locations...

Page 12: ...ked Install the 90 elbow in similar fashion NOTE BE SURE THERE IS NO WIRING OR PLUMBING IN THE CHOSEN WALL LOCATION Move the stove and pipe assembly back until the 90 elbow is flush to the wall The 2...

Page 13: ...w and spin the locator found on the rear left side of the stove Refer to figure 7 Figure 7 II FIREPLACE VENTING INSTALLATIONS 40 maximum system height without offsets 14 maximum offset refer to Figure...

Page 14: ...Hearthstone Quality Home Heating Products Inc SANTA FE Model 8761 13 III VERTICAL TERMINATION VENTING CONFIGURATIONS 40 maximum system height without offsets Figure 8...

Page 15: ...he termination must fall within the area outlined by the shaded area shown in Figure 7 Use a vinyl siding Stand off when installing against vinyl siding Horizontal sections require a 1 4 rise every 12...

Page 16: ...This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used available through your loca...

Page 17: ...nifold gas pressure must be tested The gas control valve has built in pressure taps for test gauge connections The supply line pressure must be tested to ensure it meets the minimum pressure for the t...

Page 18: ...ast a long time however they will break easily if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combust...

Page 19: ...careful not to chip the enamel when fastening the door REMOVAL OF LOG SET Caution Log set and charcoal embers will retain heat and can be very hot if previously lit Allow at least 1 hour after pilot...

Page 20: ...ol knob Never use tools WARNING The control has an interlock device If the stove has been lit it will not relight immediately After shutting off all gas flow the pilot burner cannot be relit until the...

Page 21: ...accumulation of dust lint and other debris free of obstruction safe and in good working condition To clean the firebox set the switch to the OFF position and turn off the gas at the gas control valve...

Page 22: ...WIRING INSTRUCTIONS Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Attention A...

Page 23: ...CLIP 2310 850 HEAT EXCHANGER BASE 7200 351 ORIFICE BURNER HOOD LP 51 SPUD 2310 860 HEAT EXCHANGER 7211 390 3 WAY PILOT HOOD W CLIP 2310 240 EXHAUST BAFFLE 7211 009 PILOT GAS TUBE 3030 028 GLASS 17 15...

Page 24: ...23 07044 2 RATING LABEL...

Page 25: ...mmer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas pressure A Check for proper inlet...

Page 26: ...ut the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning device as this may damage the orific...

Page 27: ...uctions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burner near the orifice usually creat...

Page 28: ...anship Firebox and firebox baffle against breakage cracking or burn through Convective heat exchanger against breakage cracking or burn through Burners air shutters and orifices against breakage crack...

Page 29: ...o comply with Hearthstone s or a Dealer s request to ship the part or the Stove to Hearthstone or a Dealer as the case may be THE WARRANTIES CONTAINED IN THIS DOCUMENT ARE EXCLUSIVE AND ARE GIVEN BY H...

Page 30: ...r after the Purchase Date Hearthstone will pay for warranty labor performed by a Dealer at Hearthstone s published labor rates in effect at the time the labor is performed Thereafter the Original Purc...