The Sterling requires minimal routine
maintenance and care. The unit should always be
cool and off when being cleaned or maintained.
The unit should receive regular cleaning on,
under and around the stove to prevent the build up
of dust and lint. The exterior surfaces of the unit can
be cleaned using soap and water and a soft cloth.
Do not use abrasive or chemical cleaners and take
care not to scratch the stones, glass or enamel finish
(if so equipped) when cleaning the unit. The use of
chemical or wax-based cleansers or polishes is not
recommended due to the potential for discoloration
of the stones when the residue of the cleansers or
polishes is exposed to heat.
The firebox should receive periodic cleaning to
prevent the accumulation of dust, lint and other
debris. To clean the firebox, set the thermostat to
the OFF position, and turn off the gas at the gas
control valve. When the unit is cool, unfasten the
front door and carefully remove the decorative
ceramic fiber log set taking care not to damage the
logs or chip the enamel cast iron. Clean the entire
firebox, the burner tubes and carefully vacuum the
entire surface of the log set. Take care to
thoroughly vacuum the ports (holes) along the top of
the burner tubes.
With the decorative ceramic fiber logs out of the
firebox, fasten the door shut and momentarily light
the unit according to the lighting instructions
described elsewhere in this manual. Check to
ensure that a flame is burning from each burner port.
The pilot light flame should be large enough to
engulf the sensor/thermocouple as described
elsewhere in this manual
(Initial Adjustments: Pilot
Adjustment)
. Turn the unit off by setting the
thermostat to off, turning off the gas at the gas
control valve. Allow the unit to cool.
Check and clean any burner ports which are not
burning or burning properly. Clean burner ports
using a soft brush or vacuum cleaner. If the pilot
light flame height needs adjustment it should be
adjusted by qualified service personnel as described
elsewhere in this manual.
Complete the cleaning procedure by carefully
replacing the log set within the firebox as described
elsewhere in this manual. Close and fasten the front
door. Turn on the gas, light the unit and check for
proper operation.
Regularly check that the area around the Sterling
is kept free and clear from combustible materials,
gasoline and other flammable vapors and liquids.
Check that the flow of combustion and ventilation air
is not obstructed.
Note:
If any replacement parts are needed,
contact your local dealer for parts. Do not
substitute materials.
Once a year the unit and venting system should
be inspected by qualified service personnel to
ensure that they are clean, free of obstruction, safe
and in good working order. If service or
maintenance is required it should be performed by
qualified service personnel.