HearthStone Quality Home Heating Products Inc
STERLING Ht Gas-Fired Direct Vent heater
R
ATING
L
ABEL
SERIAL #
MODEL #
8532-
MODEL NAME: STERLING-Ht DIRECT VENT GAS FIREPLACE HEATER
LISTED: VENTED GAS FIREPLACE HEATER
TESTED TO: ANSI Z21.88-2002 CSA 2.33-M02, CAN/CGA-2.17-M91
CE RTIFIED FOR CANA DA/HO MOLOGUE P OUR L E CANADA
ALSO F OR MO BILE HOME I NSTAL LATION
INPUT RATING (Btu/hr) 0-2000 ft
INPUT RATING (Btu/hr) 2000-4500 ft
ORIFICE SIZE (DMS) 0-2000 ft
ORIFICE SIZE (DMS) 2000-4500 ft
MANIFOLD PRESSURE - LO (in. W.c./kpa)
MANIFOLD PRESSURE - HI (in. W.c./kpa)
MINIMUM INLET PRESSURE (in.w.c./kpa)
MINIMUM INPUT RATING (btu/hr) 0/2000 ft
MAXIMUM OUTPUT (btu/hr) 0-2000 ft
33,000
31,500
43, 52
44, 53
1.2/0.3
3.5/0.87
5.0/1.24
13,600
26,600
33,000
31,900
55, 63
56, 64
3.3/0.8
10.0/2.48
11.0/2.88
11,900
27,400
NG
LP
MINIMUM CLEARANCES TO COMBUSTIBLES
EDGE OF TOP TO: CEILING / MANTLE (17”)
BACK OF STOVE TO: BACKWALL
EDGE OF SIDE TO: SIDEWALL
14” / 356mm
2” / 50 mm
4” / 100 mm
ELECTRICAL RATING:
115 VOLTS @ 60Hz, LESS THAN 2.0A
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL.
MANUFACTURED BY: HearthStone, MORRISVILLE, VERMONT 05661
Date of Manufacture
2004 2005 2006 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
DO NOT REMOVE OR COVER THIS LABEL
MADE IN USA
3300-565
FUEL TYPE:
Several Optional kits are available through HearthStone or your local HearthStone dealer. A blower assembly
may be used
, spark screen (kit# 95-69320), top exit(kit# 95-60320), and two different remote controls
(kit #90-56912 & kit #90-56914) are optional as well.
(kit# 95-57320)
This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used. If the vent air intake system is
disassembled for any reason, reinstall per the instructions provided with the initial instructions. This vented gas fireplace
heater is not for use with air filters. This appliance must be properly connected to a venting system in accordance with the
manufacturer’s installation instructions.
CAUTION: DO NO T OPERATE WITH GLASS REMOVED, CRACKED, OR BROKEN.
Replacement on the panel should be done by a licensed or qualified service person.
CAUTIONNER: N’op re l’appareil avec le verra enl ve, craque ou casse. Le
remplacement du panneau devrait tre fait par une personne de service qualifi ou autoris .
è
ê
è
é
é
This appliance must be installed in accordance with the local
codes, if any, if not; follow the National Fuel Gas Code, ANSI
Z223.1 or Canadian Installation Codes, CAN/CGA B149.
WARNING: Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Refer to the
owner's information manual provided with this appliance. For
assistance or additional information consult a qualified installer,
service agency or the gas supplier.
(Installer
l'appareil selon les codes ou ré
glements locaux, ou, en l'absence de tels réglements, selon les
Codes d'installation CAN/CGA-B149.)
(L'AVERTISSEMENT:
L'installation inconvenante, ajustement, modification, service ou
entretien peut causer le dommages de propriété ou blessure.
Référer au manuel d'information de propriétaire fourni cet appareil.
Pour l'assistance ou information supplémentaire consulte un
qualifiée installeur, agence de service ou le fournisseur de gaz.)
38,000
36,900
38, 51
39, 52
1.2/0.3
3.5/0.87
5.0/1.24
13,900
30,200
38,000
37,600
53, 63
54, 64
3.3/0.8
10.0/2.48
11.0/2.88
11,600
31,300
NG
LP
5” x 8” VENTING
4” x 6” VENTING
25