Hearthstone Quality Home Heating Products, Inc
STERLING-
Ht
Model 8532
7
18" (458mm)
3" (76mm)
14" (355mm)
3" (76mm)
Corner Installations
2" (51mm)
Floor
4" (102mm)
2" (51mm)
Parallel Installations
1" (26mm)
2" (51mm)
Mantel Installations
C
LEARANCE TO
C
OMBUSTIBLES
SPECIFICATIONS:
L
ISTED
:
D
IRECT
V
ENT
G
AS
H
EATER
Model:
8532
-
Sterling Ht DV
Testing Agency:
Intertek Testing Services NA, Inc. (ITS)
Tested to:
ANSI Z21.88-1998
CSA 2.33-M98 CAN/CGA 2.17
* You may keep your orifices the same if you wish to burn at the lower 33,000 btus with the top exit kit.
Venting Exit Type
Rear Exit – 5”x8” Pipe
*Top Exit – 4”x6” Pipe
Gas Type
NG LP NG LP
Input rating (Btu/hr) 0-2000ft
33,000
33,000
38,000
38,000
Maximum output (Btu/hr) 0-2000ft
26,600
27,400
30,200
31,300
Minimum input rating (Btu/hr)
13,600
11,900
13,900
11,600
Orifice size DMS 0-2000ft
43,52 55,63 38,51 53,63
Man. pressure- HI setting (in.w.c./kPa)
3.5/0.87 10.0/2.48 3.5/0.87 10.0/2.48
Man. pressure- LO setting (in.w.c./kPa)
1.2/0.3 3.3/0.8 1.2/0.3 3.3/0.8
Minimum inlet pressure (in.w.c./kPa.)
5.0/1.24 11.0/2.88 5.0/1.24 11.0/2.88
Maximum inlet pressure (in.w.c.)
7.0
13
7
13