HearthStone Quality Home Heating Products Inc
STOWE Gas-Fired Direct Vent heater
18
A
PPROVED
V
ERTICAL
T
ERMINATION
V
ENTING
C
ONFIGURATIONS WITH
N
O
E
LBOWS OR
(2) 45º O
FFSETS
(F
IGURE
2),
AND
(2) 90º E
LBOWS
(F
IGURE
3)
•
10’ minimum system height (with or without offsets)
•
35’ maximum system height
•
6’ maximum offset (refer to Figure 2)
•
12’ maximum offset (refer to Figure 3)
•
The termination must fall within the outline shown in Figures 2 & 3. Use the indicated
restriction plate position. The restriction Plate part # is 5950-922.
C
LEARANCES FROM THE
P
IPE TO
C
OMBUSTIBLES
:
1” to vertical runs
1” below and to the side of horizontal runs
2” from the top of horizontal runs
F
IGURE
2 V
ERTICAL
T
ERMINATIONS
U
SING
S
TRAIGHT
P
IPE
F
IGURE
3 V
ERTICAL
T
ERMINATIONS
U
SING
(2)
90º E
LBOWS