background image

HearthStone Quality Home Heating Products Inc

                                          

STOWE Gas-Fired Direct Vent heater

                                                                                                     

 

22

 

Cet appareil peut être installé dans un 
maison préfabriquée (mobile) déjà installée 
à demeure si les règlements locaux le 
permettent. 
Cet appareil doit être utilisé uniquement 
avec les types de gas indiqués sur la plaque 
signalétique.  Ne pas l’utiliser avec d’autres 
gas sauf si un kitde conversion certifié est 
installé.

E

LECTRICAL 

C

ONNECTIONS

 

 

NOTE:  

OPEN VALVE DOOR ON THE FRONT FOR ELECTRICAL AND GAS 

CONNECTIONS. 

 

T

HERMOSTAT

 

The ON/OFF/T’STAT switch or wall 
mounted thermostat controls the Stowe.  We 
recommend installation of the thermostat for 
more comfortable performance, however 
you may still override the thermostat by 
setting the switch to “ON”. The thermostat 
controls the unit by “calling for heat.” The 
thermostat turns the unit on when the room 
is cold, and turns the unit off once the room 
is warmed sufficiently. The thermostat is 
controlled by a 750 millivolt DC two-wire 
circuit. 

 

R

EMOTE 

C

ONTROL

 

There are two different optional remote 
controls. Both of the remote controls are 
capable of turning the unit on and off. One 
of the optional remotes also allows you to 
control the temperature of the stove, (in the 
same way the thermostat controls the 
heater), from anywhere in the vicinity of the 
unit. If “ON” & “OFF” are the only controls 
required, Kit #90-56912 can be used. If you 
would like to control the temperature via  the 
remote control, use Kit #90-56914. 
Installation instructions are provided with 
the kits. 
 

T

HERMOSTAT 

P

LACEMENT

 

The thermostat should be placed in the same 
room or living space as the unit. Typically 
5’ (1.5m) off the floor and away from any 
influences  that may cause the temperature in 
the vicinity of the thermostat to be 
unrepresentative of the room temperature in 
general. Such influences might include 
strong lighting, a heater vent from the 
central heating system, or a nearby drafty 
window. 
 
Placement  of the thermostat on an inside 
wall rather than an outside wall is 
preferable. Do not place the thermostat 
directly behind or too close to the unit, 
otherwise heat from the unit will 
immediately satisfy the thermostat and turn 
the unit off. 
 

T

HERMOSTAT 

W

IRING

 

The thermostat wire from the unit to the 
thermostat can be surface mounted, routed 
under the floor, or through walls, etc. The 
thermostat should be connected to the unit 
using a maximum of 40’ (12m) of insulated 
thermostat wire (minimum of 18 Ga.) When 
making these connections, position the 
thermostat wire so it is directed towards the 

Conditionally approved for purchased mobile 
home installation. This appliance may be 
installed in an aftermarket permanently located, 
manufactured (mobile) home, where permitted 
by local codes. 
This appliance is only for use with the type of 
gas indicated on the rating plate.  This appliance 
is not convertible for use with other gases, unless 
a certified kit is used, available through your 
local HearthStone dealer. 

Summary of Contents for Stowe 8320

Page 1: ...e fire department A qualified installer service agency or gas supplier must perform installation and service AVERTISSEMENT Assurez vous de bien suivre les instructions donn dans cette notice pour r du...

Page 2: ...thStone Quality Home Heating Products Inc STOWE Gas Fired Direct Vent heater 2 HearthStone Quality Home Heating Products 317 Stafford Avenue Morrisville Vermont 05661 E Mail Inquiry HearthStoneStoves...

Page 3: ...arranty claims if necessary Keep your original receipt in a safe place as proof of purchase Serial Number Fuel type check one Natural Gas Liquid Propane Sold by Phone Date of Purchase Installed by Pho...

Page 4: ...nstalled and the On Off Thermostat switch is set to Thermostat the wall mounted thermostat will control the on off cycling of the unit At any time you can override the thermostat with the On Off T STA...

Page 5: ...ls r glements selon les Codes d installation CAN CGA B149 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the heater and to replac...

Page 6: ...on until the unit has been inspected and approved by qualified service personnel Prior to servicing the unit turn the valve control knob clockwise to OFF The unit should be cool prior to servicing and...

Page 7: ...and ember strip SPECIFICATIONS LISTED DIRECT VENT GAS HEATER Listed DV Gas Heater Model Stowe DV Room Heater Testing Agency Intertek Testing Services NA Inc ITS Tested to ANSI Z21 88 1998 CSA 2 33 M9...

Page 8: ...gas immediately follow the What To Do If You Smell Gas warning on the cover of this Manual If you do not smell gas proceed to the next step 5 Set the ON OFF T STAT switch to ON or if the thermostat ha...

Page 9: ...gas fired heater is easily operated by the homeowner once installed and adjusted by a qualified service technician Following is a list of the controls available to the owner user A ON OFF PILOT Built...

Page 10: ...temperature of the stove from anywhere in the vicinity of the unit G BLOWER The unit may be equipped with an OPTIONAL variable blower fan available through your local HearthStone dealer Kit 93 57001...

Page 11: ...should be inspected by qualified service personnel to ensure that it is clean free of obstruction safe and in good working order If service or maintenance is required qualified service personnel shoul...

Page 12: ...he decorative ceramic logs as they are fragile and subject to damage and breakage To open the firebox remove the two upper front screws located in the grill of the front that hold the cast fa ade onto...

Page 13: ...d allow for adequate ventilation Be sure to consider the need for access to the gas control valve access door on the front of the unit as well as full access for periodic cleaning and servicing Also c...

Page 14: ...HearthStone Quality Home Heating Products Inc STOWE Gas Fired Direct Vent heater 14...

Page 15: ...HearthStone Quality Home Heating Products Inc STOWE Gas Fired Direct Vent heater 15 Possible Vent TERMINATION locations...

Page 16: ...8 32 x 3 8 Phillips Head self tapping screws NOTE If required to use the restriction plate please refer to Figure 1 for correct locations of the additional gasket restriction plate and inner adapter...

Page 17: ...o a wall or siding Note If further direction is needed for installation please refer to the venting instructions which are provided with the venting manufacturer s instructions Note A Restrictor Kit 9...

Page 18: ...m height 6 maximum offset refer to Figure 2 12 maximum offset refer to Figure 3 The termination must fall within the outline shown in Figures 2 3 Use the indicated restriction plate position The restr...

Page 19: ...rectly off the heater Use a vinyl siding standoff when installing against vinyl siding Horizontal sections require a rise every 12 of horizontal run NOTES 1 The vent must terminate within one of the r...

Page 20: ...20 APPROVED CONFIGURATION FOR FIREPLACE INSTALLATION The termination must fall within the demarcation line shown in the illustration Use the indicated restriction plate position Restriction plate 595...

Page 21: ...nto the 10 x 10 wall pass through Secure it with 4 screws not provided Install the exterior portion of the thimble in similar fashion overlapping the 2 sections Caution For building with vinyl siding...

Page 22: ...you would like to control the temperature via the remote control use Kit 90 56914 Installation instructions are provided with the kits THERMOSTAT PLACEMENT The thermostat should be placed in the same...

Page 23: ...ependently of the burner flames Installation instructions are provided with the Kit ELECTRICAL GROUNDING INSTRUCTIONS WHEN BLOWER FAN IS INSTALLED This appliance is equipped with a three prong groundi...

Page 24: ...ucts Inc STOWE Gas Fired Direct Vent heater 24 Wiring Diagram Wiring Color KEY Bk V Y Bk Bk Hearthstone c 50 70 90 10 20 30 OFF O YG 50 60 70 80 90 c 10 20 30 O Bk R G Bk Bk W Br Bk W Y Bk V W Bk B W...

Page 25: ...black iron or steel pipe only with a flexible line to the valve and to ease thread alignment but refer to local codes Internally tinned copper tubing can be used in some areas when permitted by local...

Page 26: ...pieds 610 et 1370m seulement See data plate for additional information For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods...

Page 27: ...ne layer high the 2 ounces of Charcoal Embers 5 You will not need to use all of the Charcoal Embers Keep the rest in to use in the future 6 Make sure the front is properly secured to the firebox befor...

Page 28: ...ufacturing and assembly of the unit Open windows to vent the room if necessary The off gassing and fumes will subside after the first 10 to 20 minutes of operation ODORS AND IMPURITIES A heater of thi...

Page 29: ...ced by the unit by varying the gas pressure to the main burner tube A combination of heat output and the thermostat setting affect the length of the burn cycle If your stove turns on and off too often...

Page 30: ...nnot be corrected through air shutter adjustment an adjustment must be made to the gas supply pressure or by changing the restriction plate location Qualified service personnel must preform supply lin...

Page 31: ...d not need adjustment The pilot light flame should be large enough to engulf the thermopile and thermocouple located next to the pilot but not so large as to create excessive noise or consume excessiv...

Page 32: ...to prevent the buildup of dust and lint The exterior surfaces of the unit can be cleaned using soap water and a soft cloth Do not use abrasive or chemical cleaners and take care not to scratch the gl...

Page 33: ...is kept free and clear from combustible materials gasoline and other flammable vapors and liquids Check that the flow of combustion and ventilation air is not obstructed Once a year the unit and its v...

Page 34: ...11 009 PILOT TUBE 5320 030 HEAT SHIELD SIDE OUTER 7211 018 TUBE GAS FLEX 3 8 x 12 BURNER 5320 031 HEAT SHIELD SIDE INNER 7211 020 BURNER INLET ELBOW 3 8 COMP 5320 032 HEAT SHIELD SIDE SPACER 7210 007...

Page 35: ...E After sitting for off season summer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas...

Page 36: ...the pilot assembly If the meter reading is OK but the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any meta...

Page 37: ...livery or a restricted exhaust Correct air intake exhaust flow system B Incorrect air intake exhaust flow system Causes may be B1 Blocked Burner B2 Blocked primary air B3 Blocked secondary air inlets...

Page 38: ...hoosh noise as the burner lights This is a buildup of gases prior to ignition This is more prevalent with propane LP fuel A Incorrect air to fuel ratio A1 Primary air incorrect A2 Burner ports plugged...

Page 39: ...HearthStone Quality Home Heating Products Inc STOWE Gas Fired Direct Vent heater 39 RATING LABEL...

Page 40: ...ainst the following occurrences that result from defects in material and workmanship Firebox and firebox baffle against breakage cracking or burn through Convective heat exchanger against breakage cra...

Page 41: ...yers etc 9 A defect in any part of the Stove if the Original Purchaser fails to comply with HearthStone s or a Dealer s request to ship the part or the Stove to HearthStone or a Dealer as the case may...

Page 42: ...the foregoing warranties at no charge Labor Within the first 1st year after the Purchase Date HearthStone will pay for warranty labor performed by a Dealer at HearthStone s published labor rates in ef...

Page 43: ...HearthStone Quality Home Heating Products Inc STOWE Gas Fired Direct Vent heater 43...

Reviews: