HearthStone Quality Home Heating Products Inc
STOWE Gas-Fired Direct Vent heater
7
C
ERAMIC
F
IBER
L
OG
S
AFETY
I
NFORMATION
If the decorative ceramic log material supplied with the Stowe is damaged or missing, it must be
replaced with the same, approved replacement parts supplied by the manufacturer. These
components affect the
combustion quality and safety of the heater. Do not replace fiber ceramic logs with unapproved
ceramic logs or any other material.
Always wear gloves and safety goggles while handling the log set and ember strip.
SPECIFICATIONS:
L
ISTED
:
D
IRECT
V
ENT
G
AS
H
EATER
Listed:
DV Gas Heater
Model:
Stowe DV Room Heater
Testing Agency:
Intertek Testing Services
NA Inc. (ITS)
Tested to:
ANSI Z21.88-1998, CSA 2.33-
M98, CAN/CGA2.17
Certified for use by:
Board of State Examiners of Plumbers and Gasfitters
100 Cambridge Street, Room 1511
Boston, Massachusetts
02202
NG
LP
Input rating (Btu/hr) 0-2000ft
25,000 25,000
Maximum output (Btu/hr) 0-2000ft
24,400 24,000
Minimum input rating (Btu/hr)
14,500 14,300
Orifice size DMS 0-2000ft
40
53
Man. pressure- HI setting (in.w.c./kPa)
3.5/0.87 10.0/2.48
Man. pressure- LO setting (in.w.c./kPa)
1.2/0.30 3.3/0.80
Inlet pressure-HI (in.w.c./kPa.)
7.0/1.74 13.0/2.75
Inlet pressure-Lo (in.w.c./kPa)
5.0/1.24 11.0/2.88