2.  Release  the  front  panel  by  lifting  up  and  off  of 

the stove body.  Set aside on a soft surface. 

 

 

Figure 3 

– Front Panel Removal 

3.  While holding the glass to the firebox with one 

hand in the top middle, remove the glass 
retention clips one side at a time by grasping the 
spring-loaded retention clip handle, pulling 
forward and moving the clip free of the glass 
frame hook.  Lean the glass away from the 
firebox at the top and pick straight up off of the 
stove. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Figure 4 

– Glass Removal 

 

4.   Reinstall by reversing the previous steps. 

 
Clearances to Combustibles

 

 

 

Note: Ensure clearances are in accordance with 
local  installation  codes  and  the  requirements  of 
the  gas  supplier.  Dégagement  conforme  aux 
codes  d’installation  locaux  et  aux  exigences  du 
foumisseunde gaz.

 

 

Due  to  high  surface  temperatures,  locate  the 
unit  out  of  traffic  areas  and  away  from  furniture 
and  draperies.  Do  not  place  clothing  and  other 
flammable material on or near the heater. When 
positioning  the  unit  always  maintain  adequate 
clearances  around  air  openings  into  the 
combustion  chamber  and  allow  for  adequate 
ventilation. Minimum clearances to combustibles 
must be maintained as shown in Figures 5 - 8.

 

Note:

  The  rear  clearance  to  combustibles  is 

determined  by  either  the  unit’s  or  the  vent  pipe’s 
minimum  clearance,  depending  on  whether  the 
installation calls for vertical rise within the room or a 
rear  exit,  through-the-wall  vent  pipe.    Ensure  you 
consider the need for access to the gas control valve 
access  door  on  the  front  of  the  unit  as  well  as  full 
access  for  periodic  cleaning  and  servicing.  Also 
consider  clearance  for  the  blower  assembly  if 
present, or planned in the future 

 

 

CAUTION:  THESE  CLEARANCES  REPRESENT 

MINIMUM 

DISTANCES  IN  ALL  CASES,  WHICH, 

THROUGH 

TESTING 

IN 

AN 

INDEPENDENT 

LABORATORY  TO  ANSI  AND  CSA  STANDARDS, 
WILL 

PREVENT 

FIRE 

OR 

SPONTANEOUS 

COMBUSTION.  WE  DO  NOT  CONTROL  THE 
COMBUSTIBLE  MATERIALS  EXPOSED  TO  HEAT 
BY 

THIS 

PRODUCT; 

THEREFORE, 

AN 

ASSESSMENT 

MUST 

BE 

MADE 

BY 

THE 

INSTALLER  TO  PREVENT  CONSEQUENTIAL 
DAMAGE OF WALLS AND FLOORING. 

 
Hearth Requirement/Floor Protection 

You  can  place  the  Stowe  directly  on  any  non-
combustible  surface  or  on  a  wood  floor.    When 
placing  the  Stowe  on  any  other  type  of  combustible 
surface  you  must  install  a  panel  made  of  metal, 
wood,  stone,  or  glass  under  the  appliance.  The 
panel must extending the full width and depth of the 
appliance. Installations must meet all local codes. 
 
 
 
 

 

 

Summary of Contents for Stowe 8324

Page 1: ...t perform installation and service of this appliance In the Commonwealth of Massachusetts all installation of gas lines and gas fittings must be performed by a licensed gas fitter or licensed plumber...

Page 2: ...Page 1 of 33 Intentionally Blank...

Page 3: ...pt in a safe place as proof of purchase Serial Number Fuel type Natural Gas Liquid Propane Sold by Date of Purchase Address Phone E mail Website Installed by Date of Installation Address Phone E mail...

Page 4: ...loor Protection 9 Venting Information 10 Venting Connection 10 Approved Systems 11 Minimum Venting 12 Electrical System Information 16 Gas Supply Connections 17 Gas Connections 18 Initial Leak Check 1...

Page 5: ...s 02202 Manufactured and Warranted by Hearthstone Quality Home Heating Products Inc 317 Stafford Ave Morrisville VT 05661 8695 USA www hearthstonestoves com Figure 1 Stowe DV Dimensions Specification...

Page 6: ...nit will remain appealing while providing years of quality performance The installation must conform to local codes or in the absences of local codes the current National Fuel Gas Code ANSI Z223 1 NFP...

Page 7: ...E COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI ACCOMPAGNENT L APPAREIL Hot Surfaces Certain exposed surfaces of the Stowe will reach high temperatu...

Page 8: ...INSTALLATION PREPARATION CODES Adhere to all local codes or in their absence the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 or CAN CGA B149 Installer l appareil selon les codes o...

Page 9: ...still occur during transit Take care to inspect for damage when unpacking and installing the unit DO NOT INSTALL OR PUT INTO SERVICE A DAMAGED OR INCOMPLETE HEATER Remove the shrink wrap and other pa...

Page 10: ...adequate ventilation Minimum clearances to combustibles must be maintained as shown in Figures 5 8 Note The rear clearance to combustibles is determined by either the unit s or the vent pipe s minimum...

Page 11: ...tone Quality Home Heating Products Inc STOWE Model 8324 10 Figure 5 Minimum Wall Clearances Figure 6 Corner Clearances Figure 7 Horizontal Vent Mantle Clearance Figure 8 Snorkel Termination Mantle Cle...

Page 12: ...RNING IN HIGH WIND AREAS AND PARTICULARLY COLD CLIMATES IT MAY BE NECESSARY TO HEAT YOUR VENT SYSTEM WITH THE PILOT PRIOR TO IGNITION OF THE MAIN BURNER IN THESE INSTANCES IT IS RECOMMENDED THAT YOU L...

Page 13: ...88 1999 CSA 2 33 M99 test methods this installation has been tested and approved by Intertek Testing Services with an appropriate test The code authority having jurisdiction must be consulted prior to...

Page 14: ...e wall Ensure both of the retaining straps extend through interior wall thimble Before attaching the vent termination to the outside of the house run a bead of non hardening mastic around its outside...

Page 15: ...CAN We strongly recommend 12 inches particularly where strong winds prevail H Not to be installed within 15 feet 4 5m above a meter regulator assembly within 3 feet 91cm horizontally from the center l...

Page 16: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 15 Figure 13 Venting Termination Diagram...

Page 17: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ATTENTION AU MOMENT DE L ENTRETIEN DES COMMANDES TIQUETEZ TOUS LES FILS AVANT LE D BRANCHEMENT DES ERREURS DE...

Page 18: ...es equal to or greater than psig Over pressurizing can damage the control resulting in leakage or control malfunction NOTICE A QUALIFIED TECHNICIAN MUST CONNECT THE HEATER TO THE GAS SUPPLY AND LEAK T...

Page 19: ...a fire or explosion GAS CONNECTIONS Connection Main Gas Tubing connections 1 Do NOT use pipe joint compound or Teflon PTFE tape 2 Slip nut and ferrule over tubing 3 Slide nut and ferrule into place a...

Page 20: ...gs will last a long time however they will break if subjected to rough or improper handling Exact positioning of the log set is required in order to obtain a pleasing flame pattern and efficient combu...

Page 21: ...n 7 Place small tufts of the Platinum Bright Embers on the burner and log surfaces for additional glow as desired do not block burner ports Figure 24 Platinum Bright Embers Enlarged to Show Detail REM...

Page 22: ...l valve Before lighting smell or use a gas detector all around the appliance area to check for gas leaks Be sure to test near the floor because some gases LPG are heavier than air and will settle on t...

Page 23: ...erly adjusted and installed thermostat By adjusting the variable output control located on the gas control valve the rate of heat output is varied to meet the heating requirements of the season Choosi...

Page 24: ...aft if necessary Controlling the draft also changes the aesthetics of the flame The restrictor plate has a large range of unlimited settings see Figures 29 30 The adjustment point is on the left side...

Page 25: ...dic cleaning to prevent the accumulation of dust lint and other debris To clean the firebox set the switch to the OFF position and turn off the gas supply to the valve When the unit is cool remove the...

Page 26: ...rom the glass by grasping one end and pulling firmly Clean off as much of the hanging fiber hairs as possible 2 Locate the 3 4 x 1 16 flat tape gasket Peel the adhesive protecting paper away from one...

Page 27: ...0 VALVE SIT UNIVERSAL 3160 107 GASKET REAR ORIFICE PLATE 7211 370 PILOT TOP CONV 3 WAY 3160 150 GASKET HEAT EXCHANGER 4 x14 5 7211 588 BURNER 3160 152 GASKET PILOT 1 75 x3 ADHESIVE BACK 3160 155 GASKE...

Page 28: ...er sitting for off season summer pilot assembly may be dirty E Clean or replace the pilot assembly 2 Pilot will not stay lit after carefully following lighting instructions A Low or too high gas press...

Page 29: ...bly If the meter reading is OK but the burner does not come on replace the gas valve C Plugged burner orifice C Remove and check burner orifice clean or replace Note do not use any metal cleaning devi...

Page 30: ...lear obstructions B3 Clear obstructions C If gas pressures are correct and the flames stay the same adjust the air shutter for a proper burn 9 Burner flashback Air gas mixture ignites inside the burne...

Page 31: ...Hearthstone Quality Home Heating Products Inc STOWE Model 8324 30 07044 2 RATING LABEL...

Page 32: ...ot listed elsewhere Any parts repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the ori...

Page 33: ...Such parts that are subject to normal wear and tear during the warranty period such as paint gaskets baffles refractory materials ash grates and glass 4 Damage resulting from installation modificatio...

Page 34: ...rts for repair the return of the appliance for repair or to schedule a Dealer service call The Original Purchaser should refer to the Dealer Network search engine contained on Hearthstone s Web site w...

Reviews: